HomeMy WebLinkAboutRADEMACHER 23-25, 38-25, 39-25 - Well Abandonment Report - Kerr McGee - 3/29/2019Status
VISU0909SURF 12+1/4 8+5/8 24 909 430
CBL2,8207,6051ST 7+7/8 4+1/2 11.6 7,605 630
CBL8341,512S.C. 1.1 1,500 130
Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement TopCement Bot
Casing History
Subsequent Report of Abandonment
Details:
If yes, explain details below
If yes, explain details below
Yes NoWellbore has Uncemented Casing leaks:
NoYesFish in Hole:
790Estimated Depth:NoYesCasing to be pulled:
Other
Mechanical ProblemsProduction Sub-economicDryReason for Abandonment:
-104.94729440.193547 Longitude:
GPS Data:
Only Complete the Following Background Information for Intent to Abandon
Cody Mattson2.603/19/2009 GPS Instrument Operator's Name:PDOP Reading:Date of Measurement:
Latitude:
90750Field Number:Field Name:WATTENBERG
Federal, Indian or State Lease Number:
Meridian:668W Range:Township:3N 25Section:QtrQtr:
23-25 Well Number:
SWSE
County:WELD
Location:
RADEMACHERWell Name:
05-123-27141-00API Number
This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete, this
form shall again be submitted as a Subsequent Report of the actual work completed. The approved intent shall be valid for six months after the approval
date, after that period, a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration
and the proposed configuration with plugs set.
A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellbore
diagram showing plugs that were set and casing remaining in the hole, the job summaries from all plugging contractors used, including wireline and
cementing (third party verification) and any logs that may have been run during abandonment.
State of Colorado
Oil and Gas Conservation Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109
WELL ABANDONMENT REPORT
FORM
6
Rev
05/18
Notice of Intent to Abandon
cheryl.light@anadarko.comEmail:
(720) 929-7461Fax:
(720) 929-6461Phone:
Zip:80217-
3779
COState:DENVER
P O BOX 173779
Contact Name:
City:
CHERYL LIGHT
Address:
KERR MCGEE OIL & GAS ONSHORE LPName of Operator:
47120OGCC Operator Number:
craig.carlile@state.co.usEmail:
Tel:(970) 629-8279Name:Carlile, Craig For "Intent" 24 hour notice required,
COGCC contact:
04/30/2018
Date Received:
Document Number:
DE ET OE ES
401624176
Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth
CODELL 7398 7416
NIOBRARA 7138 7272
Total: 2 zone(s)
Current and Previously Abandoned Zones
Page 1 of 3Date Run: 9/6/2018 Doc [#401624176] Well Name: RADEMACHER 23-25
*ATTACH JOB SUMMARY
Technical Detail/Comments:
3/5/2019Expiration Date:
NoYesFlowline/Pipeline has been abandoned per Rule 1105
Type of Cement and Additives Used:
*Cementing Contractor: *Wireline Contractor:
Plugging Date:inch casingft.
of
Additional Plugging Information for Subsequent Report Only
Casing Recovered:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged:CASING
Plug Tagged:
(Cast Iron Cement Retainer Depth)
CICR Depth
CICR Depth
CICR Depth
sacks cmt on top.withCIBP #5: Depth
sacks cmt on top.withsacks cmt on top. CIPB #4: Depth25with80CIBP #3: Depth
Set sacks in mouse holeSetsacks in rat hole
NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate
25Set sacks at surface
ft.740ft. to1110sacks half in. half out surface casing fromSet90
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. 6720ft. to7070sks cmt from25Set
sacks cmt on top.4020 with 2sacks cmt on top. CIPB #2: Depth25with7070CIBP #1: Depth
Plug Type:
NOTE: Two(2) sacks cement
required on all CIBPs.
Plugging Procedure for Intent and Subsequent Report
McCoy, Diane
Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable
orders and is hereby approved.
COGCC Approved:Date:9/6/2018
I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete.
Signed:Print Name:CHERYL LIGHT
Title:Staff Regulatory Analyst Date:4/30/2018 Email:DJREGULATORY@ANADARKO.COM
CONDITIONS OF APPROVAL, IF ANY:
Page 2 of 3Date Run: 9/6/2018 Doc [#401624176] Well Name: RADEMACHER 23-25
COA Type Description
1) Provide 48 hour notice of plugging MIRU via electronic Form 42.
2) Properly abandon on-location flowlines per Rule 1105. File electronic Form 42 once
abandonment complete. Within 30 days of an operator completing abandonment
requirements for an off-location flowline or crude oil transfer line the operator must
submit a Flowline Report, Form 44.
3) Operator shall implement measures to control unnecessary and excessive venting, to
protect the health and safety of the public, and to ensure that vapors and odors from
well plugging operations do not constitute a nuisance or hazard to public welfare.
4) If there is pressure or evidence of gas migration after placing the CIBP at 4020’, do
not pump the stub plug and shoe plug as one plug. Contact COGCC engineering for an
update to the plugging procedure
Prior to starting plugging operations a bradenhead test shall be performed if there has
not been a reported bradenhead test within the 60 days immediately preceding the start
of plugging operations.
1) If, before opening the bradenhead valve, the beginning pressure is greater than 25
psi, sampling is required.
2) If pressure remains at the conclusion of the test, or if any liquids were present during
the test, sampling is required.
The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with
Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are
collected, copies of all final laboratory analytical results shall be provided to the COGCC
within three (3) months of collecting the samples.
If there is a need for sampling, contact COGCC engineering for verification of plugging
procedure.
Attachment Check List
Att Doc Num Name
401624176 WELL ABANDONMENT REPORT (INTENT)
401624180 PROPOSED PLUGGING PROCEDURE
401624181 WELLBORE DIAGRAM
401755721 FORM 6 INTENT SUBMITTED
Total Attach: 4 Files
User Group Comment Comment Date
Permit Ready to pass form.
Niobrara and Codell productive intervals confirmed via doc# 2555555.
05/23/2018
Well File
Verification
Pass 04/30/2018
Total: 2 comment(s)
General Comments
Page 3 of 3Date Run: 9/6/2018 Doc [#401624176] Well Name: RADEMACHER 23-25
Status
VISU0910SURF 12+1/4 8+5/8 24 910 395
CBL2,8607,8351ST 7+7/8 4+1/2 11.6 7,835 690
CBL7661,530S.C. 1.1 1,525 135
Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement TopCement Bot
Casing History
Subsequent Report of Abandonment
Details:
If yes, explain details below
If yes, explain details below
Yes NoWellbore has Uncemented Casing leaks:
NoYesFish in Hole:
750Estimated Depth:NoYesCasing to be pulled:
Other
Mechanical ProblemsProduction Sub-economicDryReason for Abandonment:
-104.94705340.193456 Longitude:
GPS Data:
Only Complete the Following Background Information for Intent to Abandon
Cody Mattson2.903/19/2009 GPS Instrument Operator's Name:PDOP Reading:Date of Measurement:
Latitude:
90750Field Number:Field Name:WATTENBERG
Federal, Indian or State Lease Number:
Meridian:668W Range:Township:3N 25Section:QtrQtr:
38-25 Well Number:
SWSE
County:WELD
Location:
RADEMACHERWell Name:
05-123-27146-00API Number
This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete, this
form shall again be submitted as a Subsequent Report of the actual work completed. The approved intent shall be valid for six months after the approval
date, after that period, a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration
and the proposed configuration with plugs set.
A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellbore
diagram showing plugs that were set and casing remaining in the hole, the job summaries from all plugging contractors used, including wireline and
cementing (third party verification) and any logs that may have been run during abandonment.
State of Colorado
Oil and Gas Conservation Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109
WELL ABANDONMENT REPORT
FORM
6
Rev
05/18
Notice of Intent to Abandon
cheryl.light@anadarko.comEmail:
(720) 929-7461Fax:
(720) 929-6461Phone:
Zip:80217-
3779
COState:DENVER
P O BOX 173779
Contact Name:
City:
CHERYL LIGHT
Address:
KERR MCGEE OIL & GAS ONSHORE LPName of Operator:
47120OGCC Operator Number:
craig.carlile@state.co.usEmail:
Tel:(970) 629-8279Name:Carlile, Craig For "Intent" 24 hour notice required,
COGCC contact:
05/04/2018
Date Received:
Document Number:
DE ET OE ES
401630626
Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth
CODELL 7668 7688
NIOBRARA 7408 7538
Total: 2 zone(s)
Current and Previously Abandoned Zones
Page 1 of 3Date Run: 9/6/2018 Doc [#401630626] Well Name: RADEMACHER 38-25
*ATTACH JOB SUMMARY
Technical Detail/Comments:
3/5/2019Expiration Date:
NoYesFlowline/Pipeline has been abandoned per Rule 1105
Type of Cement and Additives Used:
*Cementing Contractor: *Wireline Contractor:
Plugging Date:inch casingft.
of
Additional Plugging Information for Subsequent Report Only
Casing Recovered:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged:CASINGPlug Type:
Plug Tagged:CASING
Plug Tagged:
(Cast Iron Cement Retainer Depth)
CICR Depth
CICR Depth
CICR Depth
sacks cmt on top.withCIBP #5: Depth
sacks cmt on top.withsacks cmt on top. CIPB #4: Depth25with80CIBP #3: Depth
Set sacks in mouse holeSetsacks in rat hole
NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate
25Set sacks at surface
ft.700ft. to1050sacks half in. half out surface casing fromSet90
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. 1475ft. to1575sks cmt fromSet10
ft. 6800ft. to7333sks cmt from35Set
sacks cmt on top.4290 with 2sacks cmt on top. CIPB #2: Depth35with7333CIBP #1: Depth
Plug Type:
NOTE: Two(2) sacks cement
required on all CIBPs.
Plugging Procedure for Intent and Subsequent Report
McCoy, Diane
Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable
orders and is hereby approved.
COGCC Approved:Date:9/6/2018
I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete.
Signed:Print Name:CHERYL LIGHT
Title:Staff Regulatory Analyst Date:5/4/2018 Email:DJREGULATORY@ANADARKO.COM
CONDITIONS OF APPROVAL, IF ANY:
Page 2 of 3Date Run: 9/6/2018 Doc [#401630626] Well Name: RADEMACHER 38-25
COA Type Description
1) Provide 48 hour notice of plugging MIRU via electronic Form 42.
2) Properly abandon on-location flowlines per Rule 1105. File electronic Form 42 once
abandonment complete. Within 30 days of an operator completing abandonment
requirements for an off-location flowline or crude oil transfer line the operator must
submit a Flowline Report, Form 44.
3) Operator shall implement measures to control unnecessary and excessive venting, to
protect the health and safety of the public, and to ensure that vapors and odors from
well plugging operations do not constitute a nuisance or hazard to public welfare.
4) Submit correct formation tops with Form 6 Subsequent Report of Abandonment.
Prior to starting plugging operations a bradenhead test shall be performed if there has
not been a reported bradenhead test within the 60 days immediately preceding the start
of plugging operations.
1) If, before opening the bradenhead valve, the beginning pressure is greater than 25
psi, sampling is required.
2) If pressure remains at the conclusion of the test, or if any liquids were present during
the test, sampling is required.
The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with
Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are
collected, copies of all final laboratory analytical results shall be provided to the COGCC
within three (3) months of collecting the samples.
If there is a need for sampling, contact COGCC engineering for verification of plugging
procedure.
Attachment Check List
Att Doc Num Name
401630626 WELL ABANDONMENT REPORT (INTENT)
401630635 PROPOSED PLUGGING PROCEDURE
401630637 WELLBORE DIAGRAM
401755742 FORM 6 INTENT SUBMITTED
Total Attach: 4 Files
User Group Comment Comment Date
Engineer Corrected setting depth of stage cement.
Moved CIBP #1 to be within 100 feet of top perf.
Formation tops on wellbore diagram are different than previously submitted.
Added plug to cover old squeeze holes.
09/06/2018
Permit Ready to pass form.
Niobrara and Codell productive interval confirmed via doc# 400133578.
05/24/2018
Well File
Verification
Pass 05/07/2018
Total: 3 comment(s)
General Comments
Page 3 of 3Date Run: 9/6/2018 Doc [#401630626] Well Name: RADEMACHER 38-25
Status
VISU0911SURF 12+1/4 8+5/8 24 911 410
CBL3,2307,5781ST 7+7/8 4+1/2 11.6 7,578 604
CBL8521,518S.C. 1.1 1,500 130
Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement TopCement Bot
Casing History
Subsequent Report of Abandonment
Details:
If yes, explain details below
If yes, explain details below
Yes NoWellbore has Uncemented Casing leaks:
NoYesFish in Hole:
820Estimated Depth:NoYesCasing to be pulled:
Other
Mechanical ProblemsProduction Sub-economicDryReason for Abandonment:
-104.94728940.193519 Longitude:
GPS Data:
Only Complete the Following Background Information for Intent to Abandon
Cody Mattson3.003/19/2009 GPS Instrument Operator's Name:PDOP Reading:Date of Measurement:
Latitude:
90750Field Number:Field Name:WATTENBERG
Federal, Indian or State Lease Number:
Meridian:668W Range:Township:3N 25Section:QtrQtr:
39-25 Well Number:
SWSE
County:WELD
Location:
RADEMACHERWell Name:
05-123-27142-00API Number
This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete, this
form shall again be submitted as a Subsequent Report of the actual work completed. The approved intent shall be valid for six months after the approval
date, after that period, a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration
and the proposed configuration with plugs set.
A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellbore
diagram showing plugs that were set and casing remaining in the hole, the job summaries from all plugging contractors used, including wireline and
cementing (third party verification) and any logs that may have been run during abandonment.
State of Colorado
Oil and Gas Conservation Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109
WELL ABANDONMENT REPORT
FORM
6
Rev
05/18
Notice of Intent to Abandon
cheryl.light@anadarko.comEmail:
(720) 929-7461Fax:
(720) 929-6461Phone:
Zip:80217-
3779
COState:DENVER
P O BOX 173779
Contact Name:
City:
CHERYL LIGHT
Address:
KERR MCGEE OIL & GAS ONSHORE LPName of Operator:
47120OGCC Operator Number:
craig.carlile@state.co.usEmail:
Tel:(970) 629-8279Name:Carlile, Craig For "Intent" 24 hour notice required,
COGCC contact:
09/07/2018
Date Received:
Document Number:
DE ET OE ES
401593865
Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth
CODELL 7411 7431
NIOBRARA 7157 7283
Total: 2 zone(s)
Current and Previously Abandoned Zones
Page 1 of 3Date Run: 10/1/2018 Doc [#401593865] Well Name: RADEMACHER 39-25
*ATTACH JOB SUMMARY
Technical Detail/Comments:
3/31/2019Expiration Date:
NoYesFlowline/Pipeline has been abandoned per Rule 1105
Type of Cement and Additives Used:
*Cementing Contractor: *Wireline Contractor:
Plugging Date:inch casingft.
of
Additional Plugging Information for Subsequent Report Only
Casing Recovered:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged:CASINGPlug Type:
Plug Tagged:CASING
Plug Tagged:
(Cast Iron Cement Retainer Depth)
CICR Depth
CICR Depth
CICR Depth2860
sacks cmt on top.withCIBP #5: Depth
sacks cmt on top.withsacks cmt on top. CIPB #4: Depth25with80CIBP #3: Depth
Set sacks in mouse holeSetsacks in rat hole
NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate
25Set sacks at surface
ft.720ft. to1115sacks half in. half out surface casing fromSet90
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casing95ft. withPerforate and squeeze at 3200
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. 2670ft. to2860sks cmt fromSet15
ft. 6740ft. to7090sks cmt from25Set
sacks cmt on top.4050 with 2sacks cmt on top. CIPB #2: Depth25with7090CIBP #1: Depth
Plug Type:
NOTE: Two(2) sacks cement
required on all CIBPs.
Plugging Procedure for Intent and Subsequent Report
McCoy, Diane
Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable
orders and is hereby approved.
COGCC Approved:Date:10/1/2018
I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete.
Signed:Print Name:CHERYL LIGHT
Title:Staff Regulatory Analyst Date:9/7/2018 Email:DJREGULATORY@ANADARKO.COM
CONDITIONS OF APPROVAL, IF ANY:
Page 2 of 3Date Run: 10/1/2018 Doc [#401593865] Well Name: RADEMACHER 39-25
COA Type Description
Prior to starting plugging operations a bradenhead test shall be performed if there has
not been a reported bradenhead test within the 60 days immediately preceding the start
of plugging operations.
1) If, before opening the bradenhead valve, the beginning pressure is greater than 25
psi, sampling is required.
2) If pressure remains at the conclusion of the test, or if any liquids were present during
the test, sampling is required.
The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with
Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are
collected, copies of all final laboratory analytical results shall be provided to the COGCC
within three (3) months of collecting the samples.
1) Provide 48 hour notice of plugging MIRU via electronic Form 42.
2) Properly abandon on-location flowlines per Rule 1105. File electronic Form 42 once
abandonment complete. Within 30 days of an operator completing abandonment
requirements for an off-location flowline or crude oil transfer line the operator must
submit a Flowline Report, Form 44.
3) Operator shall implement measures to control unnecessary and excessive venting, to
protect the health and safety of the public, and to ensure that vapors and odors from
well plugging operations do not constitute a nuisance or hazard to public welfare.
4) After pumping squeeze, shut down and shut well in at minimum 8 hours; verify gas
migration has been eliminated. If evidence of gas migration or pressure remains contact
COGCC Engineer for an update to plugging orders.
Attachment Check List
Att Doc Num Name
401593865 WELL ABANDONMENT REPORT (INTENT)
401756813 PROPOSED PLUGGING PROCEDURE
401756814 WELLBORE DIAGRAM
401780192 FORM 6 INTENT SUBMITTED
Total Attach: 4 Files
User Group Comment Comment Date
Permit NBRR top perf updated by operator via email
Passed permit review
09/17/2018
Engineer TOC on wellbore diagram is incorrect.
Proposed to cut casing at a depth where there is backside cement.
09/06/2018
Well File
Verification
Pass 04/13/2018
Total: 3 comment(s)
General Comments