Loading...
HomeMy WebLinkAboutOLANDER-62N68W - Off Location Flowline - Kerr McGee - 2/22/2019State of Colorado Oil and Gas Conservation Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Off-Location Flowline FORM 44 Rev 03/18 Document Number: OGCC RECEPTION Receive Date: 02/22/2019 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, or report abandonment of Off-Location Flowlines , Produced Water Transfer Systems, Domestic Taps, or Crude Oil Transfer Lines as required by the 1100 Series Rules. The Form shall also be submitted to report Grade 1 Gas Leaks from Flowlines per Rule 1104.k. 401948561 OFF LOCATION FLOWLINE FLOWLINE ENDPOINT LOCATION IDENTIFICATION Location ID:336115 Location Type:Production Facilities Name:OLANDER-62N68W Number:14SWSW County:WELD Qtr Qtr:NWSW Section:14 Township:2N Range:68W Meridian:6 Latitude:40.135590 Longitude:-104.975180 FLOWLINE FACILITY INFORMATION Flowline Facility ID:462205 Flowline Type:Action Type:Abandonment OFF LOCATION FLOWLINE REGISTRATION Flowline End Point Riser Latitude:40.135215 Longitude:-104.975160 PDOP:1.3 Measurement Date:08/11/2017 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336115 Location Type:Well Site Name:OLANDER-62N68W Number:14SWSW County:WELD Qtr Qtr:NWSW Section:14 Township:2N Range:68W Meridian:6 Latitude:40.135590 Longitude:-104.975180 Flowline Start Point Riser Latitude:40.135527 Longitude : -104.975445 PDOP:1.4 Measurement Date:07/23/2028 Equipment at Start Point Riser:Well No Location ID OGCC Operator Number: City: Company Name: Address: 47120 KERR MCGEE OIL & GAS ONSHORE LP P O BOX 173779 DENVER Zip:State:80217-3779 Contact Person:Mike Holle Phone:(720) 9296639 CO Email:mike.holle@anadarko.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (UNCC) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 2/22/2019 Doc [#401948561]Page 1 of 3 Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:03/04/2002 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE ABANDONMENT Date:11/15/2018 Description of Abandonment The HSR-Bear 13-14A P&A is complete. The well head was cut and capped on 11/14/2018. The entire flow line was removed on 11/15/2018. FLOWLINE FACILITY INFORMATION Flowline Facility ID:462204 Flowline Type:Wellhead Line Action Type:Abandonment OFF LOCATION FLOWLINE REGISTRATION Flowline End Point Riser Latitude:40.135215 Longitude:-104.975175 PDOP:1.4 Measurement Date:07/27/2017 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336115 Location Type:Well Site Name:OLANDER-62N68W Number:14SWSW County:WELD Qtr Qtr:NWSW Section:14 Township:2N Range:68W Meridian:6 Latitude:40.135590 Longitude:-104.975180 Flowline Start Point Riser Latitude:40.135591 Longitude : -104.975170 PDOP:1.2 Measurement Date:07/28/2017 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:07/15/2010 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE ABANDONMENT Date:11/15/2018 Description of Abandonment The Olander 1 P&A is complete. The well head was cut and capped on 11/14/2018. The entire flow line was removed on 11/15/2018. The entire tank battery was removed on 11-19/2018. No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:455918 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Date Run: 2/22/2019 Doc [#401948561]Page 2 of 3 Flowline End Point Riser Latitude:40.135210 Longitude:-104.975146 PDOP:1.5 Measurement Date:07/28/2018 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:333243 Location Type:Well Site Name:OLANDER-62N68W Number:14NESW County:WELD Qtr Qtr:NESW Section:14 Township:2N Range:68W Meridian:6 Latitude:40.136967 Longitude:-104.972086 Flowline Start Point Riser Latitude:40.136966 Longitude : -104.972065 PDOP:4.2 Measurement Date:07/28/2018 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:11/01/2005 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE REMOVAL FROM SERVICE Date: Description of Removal from Service No Location ID mike.holle@anadarko.com SDA 02/22/2019 Mike Holle COGCC Approved:Director of COGCC Date: Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. The HSR-Bear 13-14A P&A is complete. The well head was cut and capped on 11/14/2018. The entire flow line was removed on 11/15/2018. HSR-BEAR 13-14A 05-123-20355 FL-HSR BEAR 13-14A The Olander 1 P&A is complete. The well head was cut and capped on 11/14/2018. The entire flow line was removed on 11/15/2018. The entire tank battery was removed on 11-19/2018. OLANDER 1 05-123-07693 FL-OLANDER 1-14 Comments OPERATOR COMMENTS AND SUBMITTAL Attachment Check List Att Doc Num Name Total Attach: 0 Files Date Run: 2/22/2019 Doc [#401948561]Page 3 of 3