Loading...
HomeMy WebLinkAboutPERRIN V 20-7 DI - Well Abandonment Report - Kerr McGee - 11/15/2018Status VISU0792SURF 12+1/4 8+5/8 24 792 230 CBL6,7108,2231ST 7+7/8 4+1/2 11.6 8,223 320 CBL3,8005,150Stage Tool 5,140 230 Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement TopCement Bot Casing History Subsequent Report of Abandonment Details: If yes, explain details below If yes, explain details below Yes NoWellbore has Uncemented Casing leaks: NoYesFish in Hole: 1155Estimated Depth:NoYesCasing to be pulled: Other Mechanical ProblemsProduction Sub-economicDryReason for Abandonment: -104.91147440.125093 Longitude: GPS Data: Only Complete the Following Background Information for Intent to Abandon Paul Tappy4.805/03/2011 GPS Instrument Operator's Name:PDOP Reading:Date of Measurement: Latitude: 90750Field Number:Field Name:WATTENBERG Federal, Indian or State Lease Number: Meridian:667W Range:Township:2N 20Section:QtrQtr: 20-7 DI Well Number: SWNE County:WELD Location: PERRIN VWell Name: 05-123-19722-00API Number This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete, this form shall again be submitted as a Subsequent Report of the actual work completed. The approved intent shall be valid for six months after the approval date, after that period, a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration and the proposed configuration with plugs set. A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellbore diagram showing plugs that were set and casing remaining in the hole, the job summaries from all plugging contractors used, including wireline and cementing (third party verification) and any logs that may have been run during abandonment. State of Colorado Oil and Gas Conservation Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 WELL ABANDONMENT REPORT FORM 6 Rev 05/18 Notice of Intent to Abandon cheryl.light@anadarko.comEmail: (720) 929-7461Fax: (720) 929-6461Phone: Zip:80217- 3779 COState:DENVER P O BOX 173779 Contact Name: City: CHERYL LIGHT Address: KERR MCGEE OIL & GAS ONSHORE LPName of Operator: 47120OGCC Operator Number: tom.beardslee@state.co.usEmail: Tel:(970) 420-3935Name:Beardslee, Tom For "Intent" 24 hour notice required, COGCC contact: 11/15/2018 Date Received: Document Number: DE ET OE ES 401840621 Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth CODELL 7533 7554 J SAND 7966 7986 Total: 2 zone(s) Current and Previously Abandoned Zones Page 1 of 3Date Run: 2/27/2019 Doc [#401840621] Well Name: PERRIN V 20-7 DI *ATTACH JOB SUMMARY Technical Detail/Comments: 8/26/2019Expiration Date: NoYesFlowline/Pipeline has been abandoned per Rule 1105 Type of Cement and Additives Used: *Cementing Contractor: *Wireline Contractor: Plugging Date:inch casingft. of Additional Plugging Information for Subsequent Report Only Casing Recovered: Plug Tagged: Plug Type: Plug Tagged: Plug Type: Plug Tagged: Plug Type: Plug Tagged: Plug Type: Plug Tagged:CASING Plug Tagged: (Cast Iron Cement Retainer Depth) CICR Depth CICR Depth CICR Depth sacks cmt on top.withCIBP #5: Depth sacks cmt on top.80 with 25sacks cmt on top. CIPB #4: Depth2with4171CIBP #3: Depth Set sacks in mouse holeSetsacks in rat hole NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate 25Set sacks at surface ft.742ft. to1255sacks half in. half out surface casing fromSet220 sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at ft. ft. tosks cmt fromSet ft. ft. tosks cmt fromSet ft. ft. tosks cmt fromSet ft. ft. tosks cmt fromSet ft. 6840ft. to7460sks cmt from40Set sacks cmt on top.7460 with 40sacks cmt on top. CIPB #2: Depth2with7910CIBP #1: Depth Plug Type: NOTE: Two(2) sacks cement required on all CIBPs. Plugging Procedure for Intent and Subsequent Report Jacobson, Eric Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable orders and is hereby approved. COGCC Approved:Date:2/27/2019 I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete. Signed:Print Name:CHERYL LIGHT Title:Staff Regulatory Analyst Date:11/15/2018 Email:DJREGULATORY@ANADARKO.COM CONDITIONS OF APPROVAL, IF ANY: Page 2 of 3Date Run: 2/27/2019 Doc [#401840621] Well Name: PERRIN V 20-7 DI COA Type Description Operator to submit the Gyro survey run 11/25/2014 as indicated on submitted plugging procedure with the Form 6 SROA. If there has not been a reported Bradenhead test within 60 days of plugging this well, prior to starting plugging operations, a Bradenhead test shall be performed. 1) If, before opening the Bradenhead valve, the beginning pressure is greater than 25 psi, sampling is required. 2) If pressure remains at the conclusion of the test, or if any liquids were present during the test, sampling is required. 3) If sampling is required contact COGCC engineering for a confirmation of plugging requirements prior to placing any plugs. Sampling shall comply with Operator Guidance - Bradenhead Testing and Reporting Instructions. The Form 17 shall be submitted within 10 days of the test. 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) Prior to placing the 1,255' plug: verify that all fluid migration (liquid or gas) has been eliminated. If evidence of fluid migration or pressure remains, contact COGCC Engineer for an update to plugging orders. 3) After isolation has been verified, pump plug and displace. If cement is not circulated to surface, shut-in, WOC 4 hours then tag plug – must be at 742' or shallower and provide 10 sack plug at surface. 4) Leave at least 100’ of cement in the wellbore for each plug. 5) Properly abandon on-location flowlines as per Rule 1105. File electronic Form 42 once abandonment is complete. Within 30 days of an operator completing abandonment requirements for an off-location flowline or crude oil transfer line, the operator must submit a Flowline Report, Form 44. Operator shall implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well plugging operations do not constitute a nuisance or hazard to public welfare. Attachment Check List Att Doc Num Name 401840621 WELL ABANDONMENT REPORT (INTENT) 401840838 PROPOSED PLUGGING PROCEDURE 401840839 WELLBORE DIAGRAM 401953597 FORM 6 INTENT SUBMITTED Total Attach: 4 Files User Group Comment Comment Date Engineer Deepest Water Well within 1 Mile – 377' SB5 Base of Fox Hills - 467' 02/27/2019 Well File Verification Pass 11/19/2018 Permit Verified as drilled lat/long Verified J Sand completed interval (826887) Verified CODELL completed interval (1241363) 11/15/2018 Total: 3 comment(s) General Comments Page 3 of 3Date Run: 2/27/2019 Doc [#401840621] Well Name: PERRIN V 20-7 DI