Loading...
HomeMy WebLinkAboutFacility 485466 - Flowline Abandonment Notice - Crestone - 7/10/2025State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Flowline System FORM 44 Rev 02/20 Document Number: ECMC RECEPTION Receive Date: 07/10/2025 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre- abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906. 404237013 FLOWLINE DESCRIPTION AND TESTING Type of Fluid Transfered: Multiphase Pipe Material:Carbon Steel Max outer Diameter (inches): 2.000 Bedding Material: Native Materials Date Construction Completed: 07/18/2015 Max Anticipated Operating PSI: Testing Pressure: 125 Test Date:03/06/2023 Description of Corrosion Protection: Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and remediate any spills in accordance with the 900 series rules. Description of Integrity Management Program: 125 FLOWLINE SYSTEM FLOWLINE SYSTEM IDENTIFICATION Facility ID Number:485466 Flowline System Name: CPR Flowline FLOWLINE SYSTEM REGISTRATION A representative legal location and associated latitude and longitude near the center of the Flowline System. County:WELD Qtr Qtr:SENE Section:9 Township:2N Range:67W Meridian:6 Latitude:40.154619 Longitude:-104.892886 GPS Quality Value:Type of GPS Quality Value:Measurement Date:03/10/1978 ECMC Operator Number: City: Company Name: Address: 10633 CRESTONE PEAK RESOURCES OPERATING LLC 555 17TH STREET SUITE 3700 DENVER Zip:State:80202 Contact Person:Fred Kayser Phone:(970) 396-4900 CO Email:fkayser@civiresources.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 7/10/2025 Doc [#404237013]Page 1 of 4 Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All repairs will be completed in accordance with COGCC 1102 Series rules. Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable. The majority of flowlines are not near any known and defined public receptors or road crossings. Those that are, county permits are acquired prior to construction of county road crossings. Permit conditions contain minimum construction requirements. FLOWLINE SYSTEM ABANDONMENT VERIFICATION Date:04/11/2025 Description of Abandonment Verification: The following flowlines were removed in their entirety: 12331571_FL: services the IONE 6-8-4 (05-123-31571) 12331569_FL: services the IONE 8-6-4 (05-123-31569) 12320151_FL: services the IONE 44-4 (05-123-20151) 12331570_FL: services the IONE 6-4-4 (05-123-31570) 12319986_FL: services the IONE 43-4 (05-123-19986) 12326408_FL: services the Miller 2-4-17 (05-123-26408) 1232082312320829_FL: services the Miller CJ 17-A and 23-17 Common Line (05-123-20823, 05-123-20829) The following off-location flowlines were partially abandoned: 12320721_FL: services the Ione 11-2 (12320721_FL) 12320717_FL: services the Ione 21-2 (12320717_FL) Flowline were abandoned in place as per Rule 1105.d and verified by a third party. All other flowlines in this system will remain as previously reported. The abandoned Flowline System was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) Form 44 filed to report POST-ABANDONMENT verification. The following flowlines were removed in their entirety: 12331571_FL: services the IONE 6-8-4 (05-123-31571) 12331569_FL: services the IONE 8-6-4 (05-123-31569) 12320151_FL: services the IONE 44-4 (05-123-20151) 12331570_FL: services the IONE 6-4-4 (05-123-31570) 12319986_FL: services the IONE 43-4 (05-123-19986) 12326408_FL: services the Miller 2-4-17 (05-123-26408) 1232082312320829_FL: services the Miller CJ 17-A and 23-17 Common Line (05-123-20823, 05-123-20829) 12319986_FL servicing the IONE 43-4 (05-123-19986) was previously abandoned in place 5/7/2024 with verification submitted on Form 44 doc# 403786062. This line was removed on 6/3/2025 along with the other Ione lines ending at the same facility: Ione 10 Battery (484435). Form 44 filed to report POST-ABANDONMENT verification. The following off-location flowlines were partially abandoned: 12320721_FL: services the Ione 11-2 (12320721_FL) 12320717_FL: services the Ione 21-2 (12320717_FL) Pre-Abandonment Form 44 doc# 403981281 stated the lines would be partially ABiP and partially removed. Once in the field, crews discovered multiple lines crossing from third parties that did not populate during initial review. Because it was was not safe to remove, the lines were fully left in place. 12320721_FL does not have any spill/releases reported on a Form 19. 12320717_FL does not have any spill/releases reported on a Form 19. Updated GIS data attached. All other flowlines in this system remained as previously reported. Comments OPERATOR COMMENTS AND SUBMITTAL Date Run: 7/10/2025 Doc [#404237013]Page 2 of 4 flowlines@civiresources.com Sr. Regulatory Analyst 07/10/2025 Stephany Olsen ECMC Approved:Director of ECMC Date: Based on the information provided herein, this Flowline Report complies with ECMC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. Date Run: 7/10/2025 Doc [#404237013]Page 3 of 4 ATTACHMENT LIST Att Doc Num Name 404270274 FLOWLINE SYSTEM GIS SHP 404272394 THIRD PARTY VERIFICATION 404272395 THIRD PARTY VERIFICATION 404272396 ABANDONMENT IN PLACE DOCUMENTATION Total Attach: 4 Files COA Type Description CONDITIONS OF APPROVAL, IF ANY LIST User Group Comment Comment Date Stamp Upon Approval Total: 0 comment(s) General Comments Date Run: 7/10/2025 Doc [#404237013]Page 4 of 4