Loading...
HomeMy WebLinkAboutMILLER-62N67W - Flowline Abandonment Notice - Extraction - 3/25/2026State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Off-Location Flowline FORM 44 Rev 02/20 Document Number: ECMC RECEPTION Receive Date: 03/25/2026 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre- abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906. 404553189 OFF LOCATION FLOWLINE FLOWLINE ENDPOINT LOCATION IDENTIFICATION Location ID:317572 Location Type:Production Facilities Name:MILLER-62N67W Number:17NENE County:WELD Qtr Qtr:NENE Section:17 Township:2N Range:67W Meridian:6 Latitude:40.142918 Longitude:-104.908310 Description of Corrosion Protection Extraction's corrosion procedures are detailed in its Flowline Management SOP. Coating materials will be used that minimize internal and external corrosion, such as internally coated pipe or stainless steel for water service, and externally coated FBE on all buried steel pipe. If flowlines are repaired due to corrosion, Extraction will investigate the failure, promptly respond with the appropriate remedial actions and determine the root cause and apply corrective actions as necessary. Extraction retains records of its chemical program in the form of Failure Analysis Reports, records of chemical invoices and chemical delivery. Description of Integrity Management Program Extraction's integrity management program is detailed in its Flowline Management SOP, which covers flowline installation, operation, maintenance, inspection, testing, and repairs. Prior to beginning any project involving flowlines, Extraction ensures the project plans, flowline installation, flowline maintenance (including repairs) and all flowline inspection and testing projects meet the requirements of the Flowline Management SOP. All pressure tests on flowlines will be conducted by an independent, third party qualified to do such testing. Precautions shall be taken to protect employees and the general public. Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable. N/A ECMC Operator Number: City: Company Name: Address: 10459 EXTRACTION OIL & GAS INC 555 17TH STREET SUITE 3700 DENVER Zip:State:80202 Contact Person:Fred Kayser Phone:(970) 396-4900 CO Email:fkayser@civiresources.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 3/25/2026 Doc [#404553189]Page 1 of 4 FLOWLINE FACILITY INFORMATION Flowline Facility ID:460530 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:318191 Location Type:Well Site Name:MILLER-62N67W Number:17SWNE County:WELD Qtr Qtr:SWNE Section:17 Township:2N Range:67W Meridian:6 Latitude:40.139688 Longitude:-104.910744 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.375 Bedding Material:Native Materials Date Construction Completed:05/05/1977 Maximum Anticipated Operating Pressure (PSI):1000 Testing PSI:98 Test Date:02/22/2018 OFF LOCATION FLOWLINE Abandonment Verification Date:01/12/2026 Description of Abandonment Verification: The 12308623FL flowline serving the MILLER 32-17 (05-123-08623) was removed in its entirety. Bellholes were dug on average every 80 feet and the line pulled. Once the flowline was removed, all areas that needed it were backfilled and the land surface was graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:460531 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:323212 Location Type:Well Site Name:MILLER 62N67W Number:17NWNE County:WELD Qtr Qtr:NWNE Section:17 Township:2N Range:67W Meridian:6 Latitude:40.143845 Longitude:-104.911397 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.375 No Location ID Date Run: 3/25/2026 Doc [#404553189]Page 2 of 4 Bedding Material:Native Materials Date Construction Completed:10/12/1985 Maximum Anticipated Operating Pressure (PSI):138 Testing PSI:138 Test Date:02/22/2018 OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification Date:05/28/2020 Description of Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification: Bell holes were dug along the length of the flowline. Flowline was cut and pulled. Approximaetly 965' of 2" steel flowline (buried +/- 4' deep) was removed. Bell holes were backfilled and land surface graded. The entire flowline was removed. regulatory@civiresources.com Sr. Regulatory Analyst 03/25/2026 Stephany Olsen ECMC Approved:Director of ECMC Date: Based on the information provided herein, this Flowline Report complies with ECMC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. Form 44 filed to report POST-ABANDONMENT notification. The following flowline was removed in its entirety: 12308623FL: serviced the MILLER 32-17 (05-123-08623) Updated GIS data attached. All other flowlines will remain as previously reported. Comments OPERATOR COMMENTS AND SUBMITTAL Date Run: 3/25/2026 Doc [#404553189]Page 3 of 4 ATTACHMENT LIST Att Doc Num Name 404553189 Form44 Submitted 404596037 OFF-LOCATION FLOWLINE GIS SHP Total Attach: 2 Files COA Type Description CONDITIONS OF APPROVAL, IF ANY LIST User Group Comment Comment Date Stamp Upon Approval Total: 0 comment(s) General Comments Date Run: 3/25/2026 Doc [#404553189]Page 4 of 4