HomeMy WebLinkAboutFacility 485466 - Flowline Abandonment Notice - Crestone - 7/20/2026State of Colorado
Energy & Carbon Management Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203
Phone: (303) 894-2100 Fax: (303) 894-2109
Flowline System
FORM
44
Rev
02/20
Document Number:
ECMC RECEPTION
Receive Date:
07/20/2026
The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre-
abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or
Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report
realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906.
404710695
FLOWLINE DESCRIPTION AND TESTING
Type of Fluid
Transfered:
Multiphase
Pipe Material:Carbon Steel
Max outer Diameter
(inches):
2.000
Bedding
Material:
Native Materials
Date Construction
Completed:
07/18/2015
Max Anticipated Operating
PSI:
Testing
Pressure:
125 Test Date:03/06/2023
Description of Corrosion Protection:
Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and
fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical program
to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and remediate any
spills in accordance with the 900 series rules.
Description of Integrity Management Program:
125
FLOWLINE SYSTEM
FLOWLINE SYSTEM IDENTIFICATION
Facility ID Number:485466 Flowline System
Name:
CPR Flowline System
FLOWLINE SYSTEM REGISTRATION
A representative legal location and associated latitude and longitude near the center of the Flowline
System.
County:WELD
Qtr Qtr:SENE Section:9 Township:2N Range:67W Meridian:6
Latitude:40.154619 Longitude:-104.892886
GPS Quality Value:Type of GPS Quality Value:Measurement Date:03/10/1978
ECMC Operator Number:
City:
Company Name:
Address:
10633
CRESTONE PEAK RESOURCES OPERATING LLC
555 17TH STREET SUITE 3700
DENVER Zip:State:80202
Contact Person:Fred Kayser
Phone:(970) 396-4900
CO
Email:fkayser@sm-energy.com
Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's
One Call notification system?Yes No
Operator Information
Date Run: 7/20/2026 Doc [#404710695]Page 1 of 4
Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual basis
in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will investigate the root
cause, as well as report and remediate any spills in accordance with the 900 series rules. All repairs will be completed
in accordance with COGCC 1102 Series rules.
Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats,
sensitive areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if
applicable.
The majority of flowlines are not near any known and defined public receptors or road crossings. Those that are,
county permits are acquired prior to construction of county road crossings. Permit conditions contain minimum
construction requirements.
FLOWLINE SYSTEM ABANDONMENT VERIFICATION
Date:04/21/2026
Description of Abandonment Verification:
The following flowlines were removed:
Edith Ann 1-2 Offsite Sales
12320847_FL
12320838_FL
12326561_FL
Geist A Unit 1 Offsite Sales Line
Bellholes were dug on average every 80 feet and the line pulled. Once the flowline was removed, all areas that
needed it were backfilled and the land surface was graded.
The following flowlines were abandoned in place as they are co-located in the same trench as other active lines.
Operations were compliant with Rule 1105.d and verified by a third party:
12337788_FL
12338169_FL
12337785_FL
The following flowlines were originally planned for removal (detailed in Pre AB Doc #:404107101 and 404512119);
however, due to crop, flowlines were abandoned in place in accordance with Rule 1105.d and verified by a third
party.
12320514_FL
12320847,12320838_FL
See attached third party verifications, pressure tests, and flowline path exhibits.
The abandoned Flowline System was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
Jurisdiction County Municipality
County WELD
Comments
OPERATOR COMMENTS AND SUBMITTAL
Date Run: 7/20/2026 Doc [#404710695]Page 2 of 4
flowlines@sm-energy.com
Sr. Regulatory Analyst
07/20/2026
Stephany Olsen
ECMC Approved:Director of ECMC Date:
Based on the information provided herein, this Flowline Report complies with ECMC Rules and applicable orders and is hereby
approved.
Title:
Email:Date:
Print Name:
Signed:
I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete.
The following flowlines were removed:
Edith Ann 1-2 Offsite Sales
12320847_FL: associated with the TOWNSEND 33-5 (05-123-20847)
12320838_FL: associated with the TOWNSEND 34-5 (05-123-20838)
12326561_FL: services the GEIST 04-02-32 (05-123-26561)
Geist A Unit 1 Offsite Sales Line (originally partial abandon in place - detailed in Pre-AB Doc # 404516306, but the field
was able to safely remove the entire flowline)
Form 44 filed to report POST-ABANDONMENT verification. The following flowlines were abandoned in place:
12337788_FL: services the LOCHBUIE 2G-31H D165 (05-123-37788)
12338169_FL: services the LOCHBUIE 2H-31H D165 (05-123-38169)
12337785_FL: services the Lochbuie 2F-31H-D165 (05-123-37785)
12320514_FL: associated with the TOWNSEND 43-5 (05-123-20514)
12320847,12320838_FL: associated with the TOWNSEND 33-5 and 34-5 Common Line (12320847,12320838_FL)
The 12320514_FL does not have any associated spill/releases reported on a Form 19.
The 12320847,12320838_FL does not have any associated spill/releases reported on a Form 19.
Pressure tests attached.
Third party verifications attached.
Updated GIS data attached.
All other related flowlines will remain as previously reported.
Date Run: 7/20/2026 Doc [#404710695]Page 3 of 4
ATTACHMENT LIST
Att Doc Num Name
404710695 Form44 Submitted
404723539 PRESSURE TEST
404723540 THIRD PARTY VERIFICATION
404723542 ABANDONMENT IN PLACE DOCUMENTATION
404734804 THIRD PARTY VERIFICATION
404734805 THIRD PARTY VERIFICATION
404734806 THIRD PARTY VERIFICATION
404734811 PRESSURE TEST
404734813 PRESSURE TEST
404734826 PRESSURE TEST
404734942 FLOWLINE SYSTEM GIS SHP
404735011 ABANDONMENT IN PLACE DOCUMENTATION
404735012 ABANDONMENT IN PLACE DOCUMENTATION
Total Attach: 13 Files
COA Type Description
CONDITIONS OF APPROVAL, IF ANY LIST
User Group Comment Comment Date
Stamp Upon
Approval
Total: 0 comment(s)
General Comments