HomeMy WebLinkAboutEMERSON-62N67W - Flowline Pre-Abandonment Notice - Crestone - 5/3/2024State of Colorado
Energy & Carbon Management Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203
Phone: (303) 894-2100 Fax: (303) 894-2109
Off-Location Flowline
FORM
44
Rev
02/20
Document Number:
ECMC RECEPTION
Receive Date:
05/03/2024
The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre-
abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems,
or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register,
report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and
906.
403777454
OFF LOCATION FLOWLINE
FLOWLINE ENDPOINT LOCATION IDENTIFICATION
Location ID:470443 Location Type:Production Facilities
Name:EMERSON-62N67W Number:29SWNE
County:WELD
Qtr Qtr:SWNE Section:29 Township:2N Range:67W Meridian:6
Latitude:40.109444 Longitude:-104.909686
Description of Corrosion Protection
Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and
fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical
program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and
remediate any spills in accordance with the 900 series rules.
Description of Integrity Management Program
Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual
basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will
investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All
repairs will be completed in accordance with COGCC 1102 Series rules.
Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive
areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable.
N/A
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:470446 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
ECMC Operator Number:
City:
Company Name:
Address:
10633
CRESTONE PEAK RESOURCES OPERATING LLC
555 17TH STREET SUITE 3700
DENVER Zip:State:80202
Contact Person:James Miller
Phone:(720) 984-7460
CO
Email:jmiller@civiresources.com
Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's
One Call notification system?Yes No
Operator Information
Date Run: 5/3/2024 Doc [#403777454]Page 1 of 4
Flowline Start Point Location Identification
Location ID:Location Type:Well Site
Name:EMERSON-62N67W Number:29CSE
County:WELD
Qtr Qtr:CSE Section:29 Township:2N Range:67W Meridian:6
Latitude:40.105607 Longitude:-104.909943
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:11/09/1983
Maximum Anticipated Operating Pressure (PSI):325 Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:04/14/2022
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Emerson 3-29J (05-123-11381) was removed in its entirety via the open trench method.
The trench was backfilled and the land surface graded.
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:470445 Flowline Type:Wellhead Line Action Type:Pre-Abandonment
Notice
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:319521 Location Type:Well Site
Name:EMERSON-62N67W Number:29SWNE
County:WELD
Qtr Qtr:SWNE Section:29 Township:2N Range:67W Meridian:6
Latitude:40.112158 Longitude:-104.909962
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:12/07/1983
Maximum Anticipated Operating Pressure (PSI):250 Testing PSI:
Test Date:
No Location ID
Date Run: 5/3/2024 Doc [#403777454]Page 2 of 4
OFF LOCATION FLOWLINE Pre-Abandonment Notice
Date:06/02/2024
Pre-Abandonment 30-day Notice
Removed per Rule 1105.d.(2)
Abandoned In Place per Rule 1105.d.(2) Exceptions - select all that apply:
A. A surface owner agreement executed by a surface owner allows abandonment in place.
B. The line is subject to the jurisdiction of the federal government, and the relevant federal agency directs
abandonment in place.
Abandoned In Place per Rule 1105.d.(3)
C. The flowline or crude oil transfer line is co-located with other active pipelines or utilities or is in a recorded
right of way.
D. Removal of the line would cause significant damage to natural resources, including wildlife resources, topsoil,
or vegetation.
E. The flowline or crude oil transfer line is in a restricted surface occupancy area or sensitive wildlife habitat.
F. The flowline or crude oil transfer line or a segment of the line crosses or is within 30 feet of a public road,
railroad, bike path, public right of way, utility corridor, or active utility or pipeline crossing.
G. The flowline or crude oil transfer line or a segment of the line crosses or is within 30 feet of or from under a
river, stream, lake, pond, reservoir, wetlands, watercourse, waterway, or spring.
H. The operator demonstrates and quantifies that the removal of the flowline will cause significant emissions of
air pollutants.
Description of Pre-Abandonment Notice:
The flowline serving the EMERSON 2-29 J (05-123-11399) will be removed in its entirety via the open trench
method. Once the flowline is removed, the trench will be backfilled and the land surface will be graded.
flowlines@civiresources.com
Sr. Regulatory Analyst
05/03/2024
Stephany Olsen
ECMC Approved:Director of ECMC Date:
Based on the information provided herein, this Flowline Report complies with ECMC Rules and applicable orders and is hereby
approved.
Title:
Email:Date:
Print Name:
Signed:
I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete.
Form 44 filed to report PRE-ABANDONMENT notification. The following flowline will be removed in their entirety:
12311399_FL: services the EMERSON 2-29 J (05-123-11399)
GIS data has previously been submitted. It is anticipated that abandonment operations will start on or about 6/2/2024.
Comments
OPERATOR COMMENTS AND SUBMITTAL
Date Run: 5/3/2024 Doc [#403777454]Page 3 of 4
ATTACHMENT LIST
Att Doc Num Name
Total Attach: 0 Files
COA Type Description
CONDITIONS OF APPROVAL, IF ANY LIST
User Group Comment Comment Date
Stamp Upon
Approval
Total: 0 comment(s)
General Comments
Date Run: 5/3/2024 Doc [#403777454]Page 4 of 4