Loading...
HomeMy WebLinkAboutWandell - Flowline Abandonment Notice - Crestone - 4/4/2024State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Off-Location Flowline FORM 44 Rev 02/20 Document Number: OGCC RECEPTION Receive Date: 04/04/2024 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre- abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906. 403709421 OFF LOCATION FLOWLINE FLOWLINE ENDPOINT LOCATION IDENTIFICATION Location ID:336330 Location Type:Production Facilities Name:Wandell Number:7H-D267 County:WELD Qtr Qtr:NWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.157957 Longitude:-104.938235 Description of Corrosion Protection Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and remediate any spills in accordance with the 900 series rules. Description of Integrity Management Program Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All repairs will be completed in accordance with COGCC 1102 Series rules. Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable. N/A FLOWLINE FACILITY INFORMATION Flowline Facility ID:473086 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator OGCC Operator Number: City: Company Name: Address: 10633 CRESTONE PEAK RESOURCES OPERATING LLC 555 17TH STREET SUITE 3700 DENVER Zip:State:80202 Contact Person:James Miller Phone:(720) 984-7460 CO Email:jmiller@civiresources.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 4/4/2024 Doc [#403709421]Page 1 of 7 Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:08/30/2011 Maximum Anticipated Operating Pressure (PSI):350 Testing PSI: Test Date: OFF LOCATION FLOWLINE Abandonment Verification Date:02/06/2024 Description of Abandonment Verification: The flowline serviced the Wandell 2-0-7 (05-123-31220). It was abandoned in place as per Rule 1105.e. See attached exhibit for third party verification. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:473085 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:01/14/2005 Maximum Anticipated Operating Pressure (PSI):350 Testing PSI: Test Date: No Location ID Date Run: 4/4/2024 Doc [#403709421]Page 2 of 7 OFF LOCATION FLOWLINE Abandonment Verification Date:02/06/2024 Description of Abandonment Verification: The flowline serviced the Wandell 23-7 and Wandell 13-7 Common Line (05-123-22397, 05-123-21258). It was abandoned in place as per Rule 1105.e. See attached exhibit for third party verification. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) FLOWLINE FACILITY INFORMATION Flowline Facility ID:473089 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Date Construction Completed:09/09/2011 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification Date:09/09/2023 Description of Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification: The flowline serving the Wandell 4-4-7 is co-located located in the same trench as the Wandell 22-7 (12320999_FL )and Wandell 0-4-7 (12331210_FL). Flowline will be abandoned in place as per Rule 1105.d and verified by a third party. See attached exhibit for flowline path. No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:473087 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD No Location ID Date Run: 4/4/2024 Doc [#403709421]Page 3 of 7 Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:03/08/2003 Maximum Anticipated Operating Pressure (PSI):350 Testing PSI: Test Date: OFF LOCATION FLOWLINE Abandonment Verification Date:02/06/2024 Description of Abandonment Verification: The flowline serviced the Wandell 11-7 (05-123-21257). It was abandoned in place as per Rule 1105.e. See attached exhibit for third party verification. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) FLOWLINE FACILITY INFORMATION Flowline Facility ID:473084 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Date Construction Completed:11/14/2011 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification Date: Description of Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification: No Location ID Date Run: 4/4/2024 Doc [#403709421]Page 4 of 7 FLOWLINE FACILITY INFORMATION Flowline Facility ID:473088 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Date Construction Completed:02/23/2003 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification Date:09/09/2023 Description of Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification: The flowline serving the Wandell 12-7 is co-located located in the same trench as the Wandell 22-7 (12320999_FL) and Wandell 0-4-7 (12331210_FL). Flowline will be abandoned in place as per Rule 1105.d and verified by a third party. See attached exhibit for flowline path. No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:473083 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:336440 Location Type:Well Site Name:WANDELL Number:2N67W/7SWNW County:WELD Qtr Qtr:SWNW Section:7 Township:2N Range:67W Meridian:6 Latitude:40.155250 Longitude:-104.939370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Date Construction Completed:02/28/2003 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: No Location ID Date Run: 4/4/2024 Doc [#403709421]Page 5 of 7 OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification Date: Description of Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification: flowlines@civiresources.com Sr. Regulatory Analyst 04/04/2024 Stephany Olsen COGCC Approved:Director of COGCC Date: Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. Form 44 filed to report POST-ABANDONMENT verification. The following flowlines were abandoned in place: 12321257_FL: serviced WANDELL 11-7 (05-123-21257) 12331220_FL: serviced WANDELL 2-0-7 (05-123-31220) 12322397_FL: serviced Wandell 23-7 and Wandell 13-7 Common Line (05-123-22397, 05-123-21258) Third party verification attached. Updated GIS data attached. 12321257_FL, 12322397_FL and 12331220_FL were abandoned in place and have an associated spill/release reported on Form 19 doc # 403696254 that was closed 2/23/2024. All other related flowlines will remain as previously reported. Comments OPERATOR COMMENTS AND SUBMITTAL Date Run: 4/4/2024 Doc [#403709421]Page 6 of 7 Attachment Check List Att Doc Num Name 403734987 THIRD PARTY VERIFICATION 403735114 OFF-LOCATION FLOWLINE GIS SHP 403735212 THIRD PARTY VERIFICATION 403735656 THIRD PARTY VERIFICATION Total Attach: 4 Files COA Type Description Condtions of Approval User Group Comment Comment Date Stamp Upon Approval Total: 0 comment(s) General Comments Date Run: 4/4/2024 Doc [#403709421]Page 7 of 7