HomeMy WebLinkAboutMCCOY NWSW MULTI-WELL PAD - Flowline Abandonment Notice - Crestone - 4/3/2024State of Colorado
Energy & Carbon Management Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203
Phone: (303) 894-2100 Fax: (303) 894-2109
Off-Location Flowline
FORM
44
Rev
02/20
Document Number:
OGCC RECEPTION
Receive Date:
04/03/2024
The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre-
abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems,
or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register,
report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and
906.
403708531
OFF LOCATION FLOWLINE
FLOWLINE ENDPOINT LOCATION IDENTIFICATION
Location ID:311412 Location Type:Production Facilities
Name:MCCOY NWSW MULTI-WELL PAD Number:0-6-5
County:WELD
Qtr Qtr:NWSW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.166300 Longitude:-104.921110
Description of Corrosion Protection
Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and
fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical
program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and
remediate any spills in accordance with the 900 series rules.
Description of Integrity Management Program
Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual
basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will
investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All
repairs will be completed in accordance with COGCC 1102 Series rules.
Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive
areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable.
N/A
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466091 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
OGCC Operator Number:
City:
Company Name:
Address:
10633
CRESTONE PEAK RESOURCES OPERATING LLC
555 17TH STREET SUITE 3700
DENVER Zip:State:80202
Contact Person:James Miller
Phone:(720) 984-7460
CO
Email:jmiller@civiresources.com
Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's
One Call notification system?Yes No
Operator Information
Date Run: 4/3/2024 Doc [#403708531]Page 1 of 7
Flowline Start Point Location Identification
Location ID:311412 Location Type:Well Site
Name:MCCOY NWSW MULTI-WELL PAD Number:0-6-5
County:WELD
Qtr Qtr:NWSW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.166300 Longitude:-104.921110
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:05/01/1998
Maximum Anticipated Operating Pressure (PSI):100 Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Abandonment Verification
Date:02/02/2024
Description of Abandonment Verification:
The flowline serving the MCCOY 13-05 (05-123-19570) was removed in its entirety via the open trench method. The
trench was backfilled and the land surface graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466094 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:318173 Location Type:Well Site
Name:MCCOY-62N67W Number:5SESW
County:WELD
Qtr Qtr:SESW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.162856 Longitude:-104.918034
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:04/24/1976
Maximum Anticipated Operating Pressure (PSI):100 Testing PSI:
Test Date:
No Location ID
Date Run: 4/3/2024 Doc [#403708531]Page 2 of 7
OFF LOCATION FLOWLINE Abandonment Verification
Date:02/02/2024
Description of Abandonment Verification:
The flowline serving the MCCOY 01 (05-123-08562) was removed in its entirety via the open trench method. The
trench was backfilled and the land surface graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466095 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:331826 Location Type:Well Site
Name:MCCOY-62N67W Number:5NESW
County:WELD
Qtr Qtr:NESW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.165976 Longitude:-104.916234
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:02/29/2008
Maximum Anticipated Operating Pressure (PSI):100 Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Abandonment Verification
Date:02/02/2024
Description of Abandonment Verification:
The flowline serving the MCCOY 23-05 (05-123-21357) was removed in its entirety via the open trench method. The
trench was backfilled and the land surface graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466093 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Date Run: 4/3/2024 Doc [#403708531]Page 3 of 7
Location ID:331828 Location Type:Well Site
Name:MCCOY-62N67W Number:5SESW
County:WELD
Qtr Qtr:SESW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.161436 Longitude:-104.916084
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:03/10/2008
Maximum Anticipated Operating Pressure (PSI):100 Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Abandonment Verification
Date:02/02/2024
Description of Abandonment Verification:
The flowline serving the MCCOY 24-05 (05-123-21359) was removed in its entirety via the open trench method. The
trench was backfilled and the land surface graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466092 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:311412 Location Type:Well Site
Name:MCCOY NWSW MULTI-WELL PAD Number:0-6-5
County:WELD
Qtr Qtr:NWSW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.166300 Longitude:-104.921110
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:11/06/2007
Maximum Anticipated Operating Pressure (PSI):270 Testing PSI:
Test Date:
No Location ID
Date Run: 4/3/2024 Doc [#403708531]Page 4 of 7
OFF LOCATION FLOWLINE Abandonment Verification
Date:02/02/2024
Description of Abandonment Verification:
The flowline serving the MCCOY 02-04-05 (05-123-24365) was removed in its entirety via the open trench method.
The trench was backfilled and the land surface graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:465540 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:331827 Location Type:Well Site
Name:MCCOY-62N67W Number:5SWSW
County:WELD
Qtr Qtr:SWSW Section:5 Township:2N Range:67W Meridian:6
Latitude:40.161516 Longitude:-104.922214
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)3.000
Bedding Material:Date Construction Completed:03/11/2008
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Abandonment Verification
Date:02/02/2024
Description of Abandonment Verification:
The flowline serving the McCoy 14-5 (05-123-21358) was previously abandoned in place. At the time of removal for
the other related flowlines, it was determined this flowline could also be safely removed. It was removed in its
entirety via the open trench method. The trench was backfilled and the land surface graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
No Location ID
Form 44 filed to report POST-ABANDONMENT verification. The following flowline(s) were removed:
12308562_FL: serviced McCoy 1 (05-123-08562)
12319570_FL: serviced McCoy 13-5 (05-123-19570)
12321358_FL: serviced McCoy 14-5 (05-123-21358)
12321357_FL: serviced McCoy 23-5 (05-123-21357)
12321359_FL: serviced McCoy 24-5 (05-123-21359)
12324365_FL: serviced McCoy 2-4-5 (05-123-24365)
Updated GIS data attached.
Comments
OPERATOR COMMENTS AND SUBMITTAL
Date Run: 4/3/2024 Doc [#403708531]Page 5 of 7
flowlines@civiresources.com
Sr. Regulatory Analyst
04/03/2024
Stephany Olsen
COGCC Approved:Director of COGCC Date:
Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby
approved.
Title:
Email:Date:
Print Name:
Signed:
I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete.
Date Run: 4/3/2024 Doc [#403708531]Page 6 of 7
Attachment Check List
Att Doc Num Name
403735090 OFF-LOCATION FLOWLINE GIS SHP
Total Attach: 1 Files
COA Type Description
Condtions of Approval
User Group Comment Comment Date
Stamp Upon
Approval
Total: 0 comment(s)
General Comments
Date Run: 4/3/2024 Doc [#403708531]Page 7 of 7