Loading...
HomeMy WebLinkAboutMCCOY NWSW MULTI-WELL PAD - Flowline Abandonment Notice - Crestone - 4/3/2024State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Off-Location Flowline FORM 44 Rev 02/20 Document Number: OGCC RECEPTION Receive Date: 04/03/2024 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre- abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906. 403708531 OFF LOCATION FLOWLINE FLOWLINE ENDPOINT LOCATION IDENTIFICATION Location ID:311412 Location Type:Production Facilities Name:MCCOY NWSW MULTI-WELL PAD Number:0-6-5 County:WELD Qtr Qtr:NWSW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.166300 Longitude:-104.921110 Description of Corrosion Protection Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and remediate any spills in accordance with the 900 series rules. Description of Integrity Management Program Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All repairs will be completed in accordance with COGCC 1102 Series rules. Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable. N/A FLOWLINE FACILITY INFORMATION Flowline Facility ID:466091 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator OGCC Operator Number: City: Company Name: Address: 10633 CRESTONE PEAK RESOURCES OPERATING LLC 555 17TH STREET SUITE 3700 DENVER Zip:State:80202 Contact Person:James Miller Phone:(720) 984-7460 CO Email:jmiller@civiresources.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 4/3/2024 Doc [#403708531]Page 1 of 7 Flowline Start Point Location Identification Location ID:311412 Location Type:Well Site Name:MCCOY NWSW MULTI-WELL PAD Number:0-6-5 County:WELD Qtr Qtr:NWSW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.166300 Longitude:-104.921110 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:05/01/1998 Maximum Anticipated Operating Pressure (PSI):100 Testing PSI: Test Date: OFF LOCATION FLOWLINE Abandonment Verification Date:02/02/2024 Description of Abandonment Verification: The flowline serving the MCCOY 13-05 (05-123-19570) was removed in its entirety via the open trench method. The trench was backfilled and the land surface graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:466094 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:318173 Location Type:Well Site Name:MCCOY-62N67W Number:5SESW County:WELD Qtr Qtr:SESW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.162856 Longitude:-104.918034 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:04/24/1976 Maximum Anticipated Operating Pressure (PSI):100 Testing PSI: Test Date: No Location ID Date Run: 4/3/2024 Doc [#403708531]Page 2 of 7 OFF LOCATION FLOWLINE Abandonment Verification Date:02/02/2024 Description of Abandonment Verification: The flowline serving the MCCOY 01 (05-123-08562) was removed in its entirety via the open trench method. The trench was backfilled and the land surface graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) FLOWLINE FACILITY INFORMATION Flowline Facility ID:466095 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:331826 Location Type:Well Site Name:MCCOY-62N67W Number:5NESW County:WELD Qtr Qtr:NESW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.165976 Longitude:-104.916234 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:02/29/2008 Maximum Anticipated Operating Pressure (PSI):100 Testing PSI: Test Date: OFF LOCATION FLOWLINE Abandonment Verification Date:02/02/2024 Description of Abandonment Verification: The flowline serving the MCCOY 23-05 (05-123-21357) was removed in its entirety via the open trench method. The trench was backfilled and the land surface graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:466093 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Date Run: 4/3/2024 Doc [#403708531]Page 3 of 7 Location ID:331828 Location Type:Well Site Name:MCCOY-62N67W Number:5SESW County:WELD Qtr Qtr:SESW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.161436 Longitude:-104.916084 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:03/10/2008 Maximum Anticipated Operating Pressure (PSI):100 Testing PSI: Test Date: OFF LOCATION FLOWLINE Abandonment Verification Date:02/02/2024 Description of Abandonment Verification: The flowline serving the MCCOY 24-05 (05-123-21359) was removed in its entirety via the open trench method. The trench was backfilled and the land surface graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:466092 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:311412 Location Type:Well Site Name:MCCOY NWSW MULTI-WELL PAD Number:0-6-5 County:WELD Qtr Qtr:NWSW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.166300 Longitude:-104.921110 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Native Materials Date Construction Completed:11/06/2007 Maximum Anticipated Operating Pressure (PSI):270 Testing PSI: Test Date: No Location ID Date Run: 4/3/2024 Doc [#403708531]Page 4 of 7 OFF LOCATION FLOWLINE Abandonment Verification Date:02/02/2024 Description of Abandonment Verification: The flowline serving the MCCOY 02-04-05 (05-123-24365) was removed in its entirety via the open trench method. The trench was backfilled and the land surface graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) FLOWLINE FACILITY INFORMATION Flowline Facility ID:465540 Flowline Type:Wellhead Line Action Type:Abandonment Verification OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:331827 Location Type:Well Site Name:MCCOY-62N67W Number:5SWSW County:WELD Qtr Qtr:SWSW Section:5 Township:2N Range:67W Meridian:6 Latitude:40.161516 Longitude:-104.922214 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)3.000 Bedding Material:Date Construction Completed:03/11/2008 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE Abandonment Verification Date:02/02/2024 Description of Abandonment Verification: The flowline serving the McCoy 14-5 (05-123-21358) was previously abandoned in place. At the time of removal for the other related flowlines, it was determined this flowline could also be safely removed. It was removed in its entirety via the open trench method. The trench was backfilled and the land surface graded. The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s). Abandonment Verification (No Jurisdiction) No Location ID Form 44 filed to report POST-ABANDONMENT verification. The following flowline(s) were removed: 12308562_FL: serviced McCoy 1 (05-123-08562) 12319570_FL: serviced McCoy 13-5 (05-123-19570) 12321358_FL: serviced McCoy 14-5 (05-123-21358) 12321357_FL: serviced McCoy 23-5 (05-123-21357) 12321359_FL: serviced McCoy 24-5 (05-123-21359) 12324365_FL: serviced McCoy 2-4-5 (05-123-24365) Updated GIS data attached. Comments OPERATOR COMMENTS AND SUBMITTAL Date Run: 4/3/2024 Doc [#403708531]Page 5 of 7 flowlines@civiresources.com Sr. Regulatory Analyst 04/03/2024 Stephany Olsen COGCC Approved:Director of COGCC Date: Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. Date Run: 4/3/2024 Doc [#403708531]Page 6 of 7 Attachment Check List Att Doc Num Name 403735090 OFF-LOCATION FLOWLINE GIS SHP Total Attach: 1 Files COA Type Description Condtions of Approval User Group Comment Comment Date Stamp Upon Approval Total: 0 comment(s) General Comments Date Run: 4/3/2024 Doc [#403708531]Page 7 of 7