Loading...
HomeMy WebLinkAboutMILLER-62N67W - Flowline Pre-Abandonment Notice - Crestone - 3/20/2024State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Off-Location Flowline FORM 44 Rev 02/20 Document Number: OGCC RECEPTION Receive Date: 03/20/2024 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre- abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906. 403721403 OFF LOCATION FLOWLINE FLOWLINE ENDPOINT LOCATION IDENTIFICATION Location ID:333209 Location Type:Production Facilities Name:MILLER-62N67W Number:17SWSW County:WELD Qtr Qtr:SWSW Section:17 Township:2N Range:67W Meridian:6 Latitude:40.132897 Longitude:-104.921964 Description of Corrosion Protection Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and remediate any spills in accordance with the 900 series rules. Description of Integrity Management Program Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All repairs will be completed in accordance with COGCC 1102 Series rules. Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable. N/A FLOWLINE FACILITY INFORMATION Flowline Facility ID:469104 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator OGCC Operator Number: City: Company Name: Address: 10633 CRESTONE PEAK RESOURCES OPERATING LLC 555 17TH STREET SUITE 3700 DENVER Zip:State:80202 Contact Person:James Miller Phone:(720) 984-7460 CO Email:jmiller@civiresources.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 3/20/2024 Doc [#403721403]Page 1 of 4 Flowline Start Point Location Identification Location ID:331470 Location Type:Well Site Name:MILLER-62N67W Number:17SESW County:WELD Qtr Qtr:SESW Section:17 Township:2N Range:67W Meridian:6 Latitude:40.133370 Longitude:-104.916926 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000 Bedding Material:Date Construction Completed:04/01/2002 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification Date:07/21/2023 Description of Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment Verification: A portion of the flowline serving the Miller 24-17 (05-123-20725) will be removed to further excavate contamination at the Miller 14-17 (05-123-07960). Once the partial flowline is removed, the trench will be backfilled and the land surface will be graded. Verbal approval obtained from Ellice Devine 7/21/2023. No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:472730 Flowline Type:Wellhead Line Action Type:Pre-Abandonment Notice OFF LOCATION FLOWLINE REGISTRATION Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:333025 Location Type:Well Site Name:MILLER-62N67W Number:17SWSW County:WELD Qtr Qtr:SWSW Section:17 Township:2N Range:67W Meridian:6 Latitude:40.134302 Longitude:-104.920370 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)3.000 Bedding Material:Date Construction Completed:05/29/2008 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: No Location ID Date Run: 3/20/2024 Doc [#403721403]Page 2 of 4 OFF LOCATION FLOWLINE Pre-Abandonment Notice Date:04/18/2024 Pre-Abandonment 30-day Notice Removed per Rule 1105.d.(2) Abandoned In Place per Rule 1105.d.(2) Exceptions - select all that apply: A. A surface owner agreement executed by a surface owner allows abandonment in place. B. The line is subject to the jurisdiction of the federal government, and the relevant federal agency directs abandonment in place. Abandoned In Place per Rule 1105.d.(3) C. The flowline or crude oil transfer line is co-located with other active pipelines or utilities or is in a recorded right of way. D. Removal of the line would cause significant damage to natural resources, including wildlife resources, topsoil, or vegetation. E. The flowline or crude oil transfer line is in a restricted surface occupancy area or sensitive wildlife habitat. F. The flowline or crude oil transfer line or a segment of the line crosses or is within 30 feet of a public road, railroad, bike path, public right of way, utility corridor, or active utility or pipeline crossing. G. The flowline or crude oil transfer line or a segment of the line crosses or is within 30 feet of or from under a river, stream, lake, pond, reservoir, wetlands, watercourse, waterway, or spring. H. The operator demonstrates and quantifies that the removal of the flowline will cause significant emissions of air pollutants. Description of Pre-Abandonment Notice: Flowline is co-located located in the same trench as the Miller 2-4-17 (12326408_FL). Flowline will be abandoned in place as per Rule 1105.d and verified by a third party. See attached exhibit for flowline path. flowlines@civiresources.com Sr. Regulatory Analyst 03/20/2024 Stephany Olsen COGCC Approved:Director of COGCC Date: Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. Form 44 filed to report PRE-ABANDONMENT notification. The following flowline will be abandoned in place: 12320828_FL: services the Miller 13-17 (05-123-20828) 12320828_FL does not have any spill/releases reported on a Form 19. GIS data has previously been submitted. It is anticipated that abandonment operations will start on or about 04/19/2024. Comments OPERATOR COMMENTS AND SUBMITTAL Date Run: 3/20/2024 Doc [#403721403]Page 3 of 4 Attachment Check List Att Doc Num Name 403721413 PROPOSED ABANDONMENT LAYOUT DRAWING 403721414 PRESSURE TEST Total Attach: 2 Files COA Type Description Condtions of Approval User Group Comment Comment Date Stamp Upon Approval Total: 0 comment(s) General Comments Date Run: 3/20/2024 Doc [#403721403]Page 4 of 4