401959630
OFF LOCATION FLOWLINE
FLOWLINE ENDPOINT LOCATION IDENTIFICATION
Location ID:336437 Location Type:Well Site
Name:GEIST 'A' UNIT-63N67W Number:32SWNW
County:WELD
Qtr Qtr:SWNW Section:32 Township:3N Range:67W Meridian:6
Latitude:40.185566 Longitude:-104.919244
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:462695 Flowline Type:Wellhead Line Action Type:Abandonment
OFF LOCATION FLOWLINE REGISTRATION
Flowline End Point Riser
Latitude:40.185977 Longitude:-104.918813 PDOP:3.0 Measurement Date:11/27/2018
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:331851 Location Type:Well Site
Name:GEIST MULTI WELL PAD Number:0-2-32
County:WELD
Qtr Qtr:NWNW Section:32 Township:3N Range:67W Meridian:6
Latitude:40.186560 Longitude:-104.919680
Flowline Start Point Riser
Latitude:40.186800 Longitude
:
-104.919849 PDOP:1.1 Measurement Date:11/27/2018
Equipment at Start Point Riser:Well
No Location ID
OGCC Operator Number:
City:
Company Name:
Address:
10633
CRESTONE PEAK RESOURCES OPERATING LLC
1801 CALIFORNIA STREET #2500
DENVER Zip:State:80202
Contact Person:Schuyler Hamilton
Phone:(303) 774-4017
CO
Email:Schuyler.Hamilton@Crestonepr.com
Is the Operator a Tier One member of the Utility Notification Center of Colorado (UNCC) that participates in Colorado's
One Call notification system?Yes No
Operator Information
Date Run: 3/4/2019 Doc [#401959630]Page 1 of 3
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)3.000
Bedding Material:Date Construction Completed:02/11/2009
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE ABANDONMENT
Date:02/04/2019
Description of Abandonment
Flowline was disconnected from separator and wellhead. Flowline was flushed with 25bbls fresh water prior to
plugging. Line was verified free of hydro carbons with LEL monitor. Line was capped on both ends with 120lbs of
slurry per state NTO, then backfilled on both ends.
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:462694 Flowline Type:Wellhead Line Action Type:Abandonment
OFF LOCATION FLOWLINE REGISTRATION
Flowline End Point Riser
Latitude:40.185965 Longitude:-104.918810 PDOP:2.8 Measurement Date:11/27/2018
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:331856 Location Type:Well Site
Name:GEIST-63N67W Number:32SENW
County:WELD
Qtr Qtr:SENW Section:32 Township:3N Range:67W Meridian:6
Latitude:40.183726 Longitude:-104.916334
Flowline Start Point Riser
Latitude:40.183783 Longitude
:
-104.916137 PDOP:1.8 Measurement Date:11/27/2018
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)3.000
Bedding Material:Date Construction Completed:02/17/2004
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE ABANDONMENT
Date:02/04/2019
Description of Abandonment
Flowline was disconnected from separator and wellhead. Flowline was flushed with 25bbls fresh water prior to
plugging. Flowline was verified free of hydro carbons with LEL monitor. Line was cut below ground level. Line was
capped on both ends with 120lbs of slurry per state NTO, then backfilled on both ends.
No Location ID
Comments
OPERATOR COMMENTS AND SUBMITTAL
Date Run: 3/4/2019 Doc [#401959630]Page 2 of 3
Schuyler.Hamilton@Crestonepr.com
EHS Field Technician
03/04/2019
Schuyler Hamilton
COGCC Approved:Director of COGCC Date:
Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby
approved.
Title:
Email:Date:
Print Name:
Signed:
I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete.
Attachment Check List
Att Doc Num Name
Total Attach: 0 Files
Date Run: 3/4/2019 Doc [#401959630]Page 3 of 3