HomeMy WebLinkAboutKUGEL-62N67W - Flowline Abandonment Notice - Crestone - 7/9/2024State of Colorado
Energy & Carbon Management Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203
Phone: (303) 894-2100 Fax: (303) 894-2109
Off-Location Flowline
FORM
44
Rev
02/20
Document Number:
ECMC RECEPTION
Receive Date:
07/09/2024
The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, provide pre-
abandonment notices, or report abandonment of Off-Location Flowlines, Flowline Systems, Produced Water Transfer Systems, or
Crude Oil Transfer Lines or Systems as required by the 1100 Series Rules. The Form 44 shall also be submitted to register, report
realignment, or report abandonment of Domestic Taps, and to report Grade 1 Gas Leaks from Flowlines per Rules 610 and 906.
403783527
OFF LOCATION FLOWLINE
FLOWLINE ENDPOINT LOCATION IDENTIFICATION
Location ID:336441 Location Type:Production Facilities
Name:KUGEL-62N67W Number:18NWNW
County:WELD
Qtr Qtr:NWNW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.142055 Longitude:-104.937841
Description of Corrosion Protection
Crestone pipelines are covered in a protective external coating. Flowlines are subject to thorough inspections and
fabrication standards during installation to minimize coating and pipe defects. Crestone maintains a chemical
program to reduce internal corrosion. If a flowline is found to lack integrity, Crestone will investigate, report, and
remediate any spills in accordance with the 900 series rules.
Description of Integrity Management Program
Crestone flowlines are pressure tested prior to placing flowlines into service. Flowlines are tested on an annual
basis in accordance with COGCC 1104 series rules. If a flowline is found to lack integrity, Crestone will
investigate the root cause, as well as report and remediate any spills in accordance with the 900 series rules. All
repairs will be completed in accordance with COGCC 1102 Series rules.
Description of the construction method used for public by-ways, road crossings, sensitive wildlife habitats, sensitive
areas, and natural and manmade watercourses (i.e., open trench, bored and cased, or bored only), if applicable.
N/A
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466538 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
ECMC Operator Number:
City:
Company Name:
Address:
10633
CRESTONE PEAK RESOURCES OPERATING LLC
555 17TH STREET SUITE 3700
DENVER Zip:State:80202
Contact Person:James Miller
Phone:(720) 984-7460
CO
Email:jmiller@civiresources.com
Is the Operator a Tier One member of the Utility Notification Center of Colorado (CO811) that participates in Colorado's
One Call notification system?Yes No
Operator Information
Date Run: 7/9/2024 Doc [#403783527]Page 1 of 8
Flowline Start Point Location Identification
Location ID:336464 Location Type:Well Site
Name:KUGEL Number:2N67W/18NWNW
County:WELD
Qtr Qtr:NWNW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.144080 Longitude:-104.940050
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Date Construction Completed:06/20/2010
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:06/08/2023
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Wandell 2-8-7 (05-123-31040) will be removed in its entirety via the open trench method.
Once the flowline is removed, the trench will be backfilled and the land surface will be graded.
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466701 Flowline Type:Wellhead Line Action Type:Abandonment
Verification
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:336385 Location Type:Well Site
Name:KUGEL-62N67W Number:18SWNW
County:WELD
Qtr Qtr:SWNW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.140370 Longitude:-104.940070
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Native Materials Date Construction Completed:12/08/1999
Maximum Anticipated Operating Pressure (PSI):400 Testing PSI:
Test Date:
No Location ID
Date Run: 7/9/2024 Doc [#403783527]Page 2 of 8
OFF LOCATION FLOWLINE Abandonment Verification
Date:04/19/2024
Description of Abandonment Verification:
The flowline serving the Kugel 12-18 (05-123-19757) was removed in its entirety. Bellholes were dug on average
every 80 feet and the line pulled. Once the flowline was removed, all areas that needed it were backfilled and the
land surface was graded.
The abandoned Off-Location Flowline was located within the jurisdiction(s) of the following local government(s).
Abandonment Verification
(No Jurisdiction)
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466699 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:336453 Location Type:Well Site
Name:KUGEL-62N67W Number:18NENW
County:WELD
Qtr Qtr:NENW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.144100 Longitude:-104.936050
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Date Construction Completed:12/12/2001
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:09/03/2023
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Kugel 21-18 (05-123-20527) will be removed in its entirety via the open trench method.
Once the flowline is removed, the trench will be backfilled and the land surface will be graded.
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466700 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:333207 Location Type:Well Site
Name:KUGEL-62N67W Number:18SENW
County:WELD No Location ID
Date Run: 7/9/2024 Doc [#403783527]Page 3 of 8
Qtr Qtr:SENW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.140280 Longitude:-104.935700
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Date Construction Completed:12/20/2001
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:04/19/2024
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Kugel 22-18 (05-123-20526) will be removed in its entirety via the open trench method.
Once the flowline is removed, the trench will be backfilled and the land surface will be graded. This is an update to
the previously submitted pre-abandonment notice doc #403486710.
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466540 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:336453 Location Type:Well Site
Name:KUGEL-62N67W Number:18NENW
County:WELD
Qtr Qtr:NENW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.144100 Longitude:-104.936050
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Date Construction Completed:11/03/2004
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:09/03/2023
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Wandell 24-7 (05-123-22354) will be removed in its entirety via the open trench method.
Once the flowline is removed, the trench will be backfilled and the land surface will be graded.
No Location ID
Date Run: 7/9/2024 Doc [#403783527]Page 4 of 8
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466698 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:336464 Location Type:Well Site
Name:KUGEL Number:2N67W/18NWNW
County:WELD
Qtr Qtr:NWNW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.144080 Longitude:-104.940050
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Date Construction Completed:09/09/2001
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:06/08/2023
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Kugel 11-18 (05-123-20509) will be removed in its entirety via the open trench method.
Once the flowline is removed, the trench will be backfilled and the land surface will be graded.
No Location ID
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:472699 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:336454 Location Type:Well Site
Name:KUGEL Number:2N67W/18HNWNE
County:WELD
Qtr Qtr:NWNE Section:18 Township:2N Range:67W Meridian:6
Latitude:40.144410 Longitude:-104.931470
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)3.000
Bedding Material:Date Construction Completed:10/29/2004
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
No Location ID
Date Run: 7/9/2024 Doc [#403783527]Page 5 of 8
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
FLOWLINE FACILITY INFORMATION
Flowline Facility ID:466539 Flowline Type:Wellhead Line Action Type:
OFF LOCATION FLOWLINE REGISTRATION
Equipment at End Point Riser:Separator
Flowline Start Point Location Identification
Location ID:336464 Location Type:Well Site
Name:KUGEL Number:2N67W/18NWNW
County:WELD
Qtr Qtr:NWNW Section:18 Township:2N Range:67W Meridian:6
Latitude:40.144080 Longitude:-104.940050
Equipment at Start Point Riser:Well
Flowline Description and Testing
Type of Fluid Transferred:Multiphase Pipe Material:Carbon Steel Max Outer Diameter:(Inches)2.000
Bedding Material:Date Construction Completed:06/15/2010
Maximum Anticipated Operating Pressure (PSI):Testing PSI:
Test Date:
OFF LOCATION FLOWLINE Realignment, Out of Service, Pre-Abandonment Notice, or Abandonment
Verification
Date:06/08/2023
Description of Realignment, Out of Service, Pre-Abandonment Notice, or
Abandonment Verification:
The flowline serving the Wandell 0-6-7 (05-123-31037) will be removed in its entirety via the open trench method.
Once the flowline is removed, the trench will be backfilled and the land surface will be graded.
No Location ID
Form 44 filed to report POST-ABANDONMENT verification. The following flowline(s) were removed:
12319757_FL: serviced Kugel 12-18 (05-123-19757)
Updated GIS data attached.
All other related flowlines will remain as previously reported.
Comments
OPERATOR COMMENTS AND SUBMITTAL
Date Run: 7/9/2024 Doc [#403783527]Page 6 of 8
flowlines@civiresources.com
Sr. Regulatory Analyst
07/09/2024
Stephany Olsen
ECMC Approved:Director of ECMC Date:
Based on the information provided herein, this Flowline Report complies with ECMC Rules and applicable orders and is hereby
approved.
Title:
Email:Date:
Print Name:
Signed:
I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete.
Date Run: 7/9/2024 Doc [#403783527]Page 7 of 8
ATTACHMENT LIST
Att Doc Num Name
403798417 OFF-LOCATION FLOWLINE GIS SHP
Total Attach: 1 Files
COA Type Description
CONDITIONS OF APPROVAL, IF ANY LIST
User Group Comment Comment Date
Stamp Upon
Approval
Total: 0 comment(s)
General Comments
Date Run: 7/9/2024 Doc [#403783527]Page 8 of 8