HomeMy WebLinkAboutCARMA 41-36 - Well Abandonment Report - Kerr McGee - 10/3/2018Status
VISU0838SURF 12+1/4 8+5/8 24 838 530
CBL7,8108,0551ST 7+7/8 4+1/2 11.6 8,055 50
CBL8308,000Stage Tool 7,799 980
Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement TopCement Bot
Casing History
Subsequent Report of Abandonment
Details:
If yes, explain details below
If yes, explain details below
Yes NoWellbore has Uncemented Casing leaks:
NoYesFish in Hole:
800Estimated Depth:NoYesCasing to be pulled:
Other
Mechanical ProblemsProduction Sub-economicDryReason for Abandonment:
-104.94659440.187637 Longitude:
GPS Data:
Only Complete the Following Background Information for Intent to Abandon
Renee Doiron2.209/12/2011 GPS Instrument Operator's Name:PDOP Reading:Date of Measurement:
Latitude:
90750Field Number:Field Name:WATTENBERG
72/2840 Federal, Indian or State Lease Number:
Meridian:668W Range:Township:3N 36Section:QtrQtr:
41-36 Well Number:
NWNE
County:WELD
Location:
CARMAWell Name:
05-123-31103-00API Number
This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete, this
form shall again be submitted as a Subsequent Report of the actual work completed. The approved intent shall be valid for six months after the approval
date, after that period, a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration
and the proposed configuration with plugs set.
A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellbore
diagram showing plugs that were set and casing remaining in the hole, the job summaries from all plugging contractors used, including wireline and
cementing (third party verification) and any logs that may have been run during abandonment.
State of Colorado
Oil and Gas Conservation Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109
WELL ABANDONMENT REPORT
FORM
6
Rev
05/18
Notice of Intent to Abandon
cheryl.light@anadarko.comEmail:
(720) 929-7461Fax:
(720) 929-6461Phone:
Zip:80217-
3779
COState:DENVER
P O BOX 173779
Contact Name:
City:
CHERYL LIGHT
Address:
KERR MCGEE OIL & GAS ONSHORE LPName of Operator:
47120OGCC Operator Number:
craig.carlile@state.co.usEmail:
Tel:(970) 629-8279Name:Carlile, Craig For "Intent" 24 hour notice required,
COGCC contact:
10/03/2018
Date Received:
Document Number:
DE ET OE ES
401782815
Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth
CODELL 7445 7463
J SAND 7888 7920
NIOBRARA 7230 7322
Total: 3 zone(s)
Current and Previously Abandoned Zones
Page 1 of 3Date Run: 11/15/2018 Doc [#401782815] Well Name: CARMA 41-36
*ATTACH JOB SUMMARY
Technical Detail/Comments:
5/14/2019Expiration Date:
NoYesFlowline/Pipeline has been abandoned per Rule 1105
Type of Cement and Additives Used:
*Cementing Contractor: *Wireline Contractor:
Plugging Date:inch casingft.
of
Additional Plugging Information for Subsequent Report Only
Casing Recovered:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged: Plug Type:
Plug Tagged:CASING
Plug Tagged:
(Cast Iron Cement Retainer Depth)
CICR Depth
CICR Depth
CICR Depth
sacks cmt on top.withCIBP #5: Depth
sacks cmt on top.80 with 25sacks cmt on top. CIPB #4: Depth2with4000CIBP #3: Depth
Set sacks in mouse holeSetsacks in rat hole
NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate
25Set sacks at surface
ft.750ft. to940sacks half in. half out surface casing fromSet60
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. ft. tosks cmt fromSet
ft. 6800ft. to7150sks cmt from25Set
sacks cmt on top.7150 with 25sacks cmt on top. CIPB #2: Depth5with7830CIBP #1: Depth
Plug Type:
NOTE: Two(2) sacks cement
required on all CIBPs.
Plugging Procedure for Intent and Subsequent Report
McCoy, Diane
Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable
orders and is hereby approved.
COGCC Approved:Date:11/15/2018
I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete.
Signed:Print Name:CHERYL LIGHT
Title:Staff Regulatory Analyst Date:10/3/2018 Email:DJREGULATORY@ANADARKO.COM
CONDITIONS OF APPROVAL, IF ANY:
Page 2 of 3Date Run: 11/15/2018 Doc [#401782815] Well Name: CARMA 41-36
COA Type Description
1) Provide 48 hour notice of plugging MIRU via electronic Form 42.
2) Properly abandon on-location flowlines per Rule 1105. File electronic Form 42 once
abandonment complete. Within 30 days of an operator completing abandonment
requirements for an off-location flowline or crude oil transfer line the operator must
submit a Flowline Report, Form 44.
3) Operator shall implement measures to control unnecessary and excessive venting, to
protect the health and safety of the public, and to ensure that vapors and odors from
well plugging operations do not constitute a nuisance or hazard to public welfare.
4) If there is pressure or evidence of gas migration after placing the CIBP at 4000’,
contact COGCC engineering for an update to the plugging procedure
Prior to starting plugging operations a bradenhead test shall be performed if there has
not been a reported bradenhead test within the 60 days immediately preceding the start
of plugging operations.
1) If, before opening the bradenhead valve, the beginning pressure is greater than 25
psi, sampling is required.
2) If pressure remains at the conclusion of the test, or if any liquids were present during
the test, sampling is required.
The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with
Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are
collected, copies of all final laboratory analytical results shall be provided to the COGCC
within three (3) months of collecting the samples.
If there is a need for sampling, contact COGCC engineering for verification of plugging
procedure.
Attachment Check List
Att Doc Num Name
401782815 WELL ABANDONMENT REPORT (INTENT)
401783505 PROPOSED PLUGGING PROCEDURE
401783507 WELLBORE DIAGRAM
401840917 FORM 6 INTENT SUBMITTED
Total Attach: 4 Files
User Group Comment Comment Date
Engineer Production records indicate this well has been SI since September 2016. All shut-in wells
must pass a mechanical integrity test or be plugged and abandoned within two years of the
initial shut-in date, this form 6 intent does not extend that due date. This well is overdue for
MIT or PA.
DWR’s aquifer determination tool base of Laramie-Fox Hills = 111'
Deepest water well within one mile = 150’
Increased sacks of cement on CIBP #1 to cover stage tool.
11/15/2018
Permit Passed permit review 10/10/2018
Well File
Verification
Pass 10/10/2018
Total: 3 comment(s)
General Comments
Page 3 of 3Date Run: 11/15/2018 Doc [#401782815] Well Name: CARMA 41-36
THE PLUG & ABANDONMENT PROCESS
When a well is no longer economically producing oil and natural gas, the well is evaluated for retirement and will undergo a process called ‘plug and abandonment,' or P&A as it is often called.
To retire, or P&A, a well, the operator must submit a plug and abandonment plan to the state regulatory authority, the Colorado Oil and Gas Conservation Commission (COGCC) for approval.
Once the plan is approved by the COGCC, the operator is required to inform the municipality where the well is located. Operators also communicate with surface land and mineral owners and surrounding neighbors regarding the retirement of the well.
A workover rig arrives on-site. While the rig is on location, the
well will be plugged per the plan approved by the COGCC.
Cement is pumped into the well to cover and isolate the zones
that produce oil and natural gas.
1
2 When the plugging operation is complete, the workover rig
moves o the location, the well head is removed and the
associated flowlines are excavated. Associated surface
equipment (tanks, separators, etc.) may also be removed if it is
not serving other active wells in the area.
3 The remaining portion of the well is cut a minimum of seven
feet below the surface and an identifying marker is welded to
the top of the plugged wellbore.
4 A final report is submitted to the COGCC to certify the
wellbore has been plugged in accordance with the
regulatory requirements.
5 The site is reclaimed, or restored, to match the existing landscape.
Colorado Response Line: 1-866-248-9577 | anadarkocolorado@anadarko.com
How a A Well is Retired