HomeMy WebLinkAboutCLOVER 29-3HZ - Application for Permit-to-Drill - Kerr McGee - 11/8/2024State of Colorado
Energy & Carbon Management Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203
Phone: (303) 894-2100 Fax: (303) 894-2109
APPLICATION FOR PERMIT TO
FORM
2
Rev
05/22
Document Number:
403983098
11/07/2024
Date Received:
Well Plan: is Directional Horizontal (highly deviated)
If Well plan is Directional or Horizontal attach Deviated Drilling Plan and Directional Data.
X Vertical
Subsurface Locations
67WRng:2NTwp:29Sec:Footage at TPZ:983 FNL
FNL/FSL
1879 FWL
FEL/FWL
Top of Productive Zone (TPZ)
Measured Depth of TPZ:8107 True Vertical Depth of TPZ:7610
WELL LOCATION INFORMATION
FeetFeet
-104.912088
QtrQtr:NWNE Sec:29 Rng:67W Twp:2N Meridian:6
Latitude:40.114871 Longitude:
Footage at Surface:611 FNL
FNL/FSL
1986 FEL
FEL/FWL
Field Name:WATTENBERG Field Number:90750
Ground Elevation:4996
GPS Data:Date of Measurement:05/02/2023GPS Quality Value:1.4 PDOPType of GPS Quality Value:
Surface Location
COMMINGLE ZONESMULTIPLE ZONESSINGLE ZONEZONE TYPE
TYPE OF WELL OIL GAS COALBED OTHER:UNPLANNED SIDETRACK X
X
christina_hirtler@oxy.comEmail:
Name of Operator:KERR MCGEE OIL & GAS ONSHORE LP ECMC Operator Number:47120
Address: P O BOX 173779
City:DENVER State:CO Zip:80217-
3779
Contact Name:Christina Hirtler Phone:(720)929-6301 Fax:( )
Well Number:29-3HZ Well Name:CLOVER
FINANCIAL ASSURANCE FOR PLUGGING, ABANDONMENT, AND RECLAMATION
Sidetrack
Refile
Amend
X
Drill Deepen Re-enter Recomplete and OperateX
Federal Financial Assurance
Amount of Federal Financial Assurance $
In checking this box, the Operator certifies that it has provided or will provide at least this amount of Financial Assurance to the
federal government for this Well. (Per Rule702.a.)
ECMC Financial Assurance
The Operator has provided or will provide Financial Assurance to the ECMC for this Well.X
Surety ID Number (if applicable):20230087
Page 1 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
SURFACE AND MINERAL OWNERSHIP AT WELL’S OIL & GAS
LOCATION
Surface Owner of the land at this Well’s Oil and Gas Location: Fee State Federal Indian
Fee State Federal IndianMineral Owner beneath this Well’s Oil and Gas Location:
Surface Owner Protection Bond (if applicable):Surety ID Number (if applicable):
X
X
MINERALS DEVELOPED BY
WELL
The ownership of all the minerals that will be developed by this Well is (check all that apply):
X Fee
State
Federal
Indian
N/A
68WRng:2NTwp:25Sec:142FNL
FNL/FSL
1032
Bottom Hole Location (BHL)
FWL
FEL/FWL
Footage at BHL:
68WRng:2NTwp:25Sec:Footage at BPZ:1032 FNL
FNL/FSL
125 FWL
FEL/FWL
Base of Productive Zone (BPZ)
Measured Depth of BPZ:20192 True Vertical Depth of BPZ:7592
LOCAL GOVERNMENT PERMITTING INFORMATION
Per § 34-60-106(1)(f)(I)(A) C.R.S., the following questions pertain to the Relevant Local Government approval of the siting of the
proposed Oil and Gas Location.
SB 19-181 provides that when “applying for a permit to drill,” operators must include proof that they sought a local government siting
permit and the disposition of that permit application, or that the local government does not have siting regulations. § 34-60-106(1)(f)(I)
(A) C.R.S.
County:WELD Municipality:N/A
Does the Relevant Local Government regulate the siting of Oil and Gas Locations, with respect to this Location?
If yes, in checking this box, I hereby certify that an application has been filed with the local government with jurisdiction to approve
the siting of the proposed oil and gas location.
NoYes
ApprovedThe disposition of the application filed with the Relevant Local Government is:
Comments:WOGLA#: 1041WOGLA23-0048
Is the Surface Location of this Well in an area designated as one of State interest and subject to the requirements of §
Yes24-65.1-108 C.R.S.?
X
X
Date of Final Disposition:01/26/2024
Page 2 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
LEASE INFORMATION
Using standard QtrQtr, Section, Township, Range format describe one entire mineral lease as follows:
* If this Well is within a unit, describe a lease that will be developed by the Well.
* If this Well is not subject to a unit, describe the lease that will be produced by the Well.
(Attach a Lease Map or Lease Description or Lease if necessary.)
Township 1 North, Range 67 West, 6th P.M.
Section 8: All
Section 9: W/2, SE/4
Township 2 North, Range 67 West, 6th P.M.
Section 19: All
Section 30: SE/4
Section 32: W/2
Total Acres in Described Lease:2217 Described Mineral Lease is:
Federal or State Lease #
X Fee State Federal Indian
Distance from Well to nearest:
Building:2106 Feet
Building Unit:2294 Feet
Public Road:597 Feet
Above Ground Utility:643 Feet
Railroad:5280 Feet
Property Line:611 Feet
INSTRUCTIONS:
- Specify all distances per Rule 308.b.(1).
- Enter 5280 for distance greater than 1 mile.
- Building - nearest building of any type. If nearest
Building is a Building Unit, enter same distance for
both.
- Building Unit – as defined in 100 Series Rules.
SAFETY SETBACK
INFORMATION
OBJECTIVE FORMATIONS
Objective Formation(s)Formation Code Spacing Order Number(s)Unit Acreage Assigned to Well Unit Configuration (N/2, SE/4, etc.)
CODELL CODL 407-3584 2400 T2N-67W;19:S2;20:SW;29:W2;30:ALL
T2N-68W;24:S2;25:ALL
Page 3 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
SPACING & FORMATIONS COMMENTS
Federal or State Unit Name (if appl): Unit Number:
SUBSURFACE MINERAL
SETBACKS
Enter 5280 for distance greater than 1 mile.
Is this Well within a unit?Yes
If YES:
If NO:
Enter the minimum distance from the Completed Zone of this Well to the Unit Boundary:125 Feet
Feet434
Enter the minimum distance from the Completed Zone of this Well to the Completed Zone of an offset Well within the same
unit permitted or completed in the same formation:
Enter the minimum distance from the Completed Zone of this Well to the Lease Line of the described lease:Feet
Feet
Enter the minimum distance from the Completed Zone of this Well to the Completed Zone of an offset Well producing from
the same lease and permitted or completed in the same formation:
Exception Location
If this Well requires the approval of a Rule 401.c Exception Location, enter the Rule or spacing order number and attach the
Exception Location Request and Waivers.
Beneficial reuse or land application plan submitted?Yes
Reuse Facility ID:or Document Number:
DRILLING PROGRAM
Proposed Total Measured Depth:20192 Feet
Distance from the proposed wellbore to nearest existing or proposed wellbore belonging to another operator, including plugged wells:
Will a closed-loop drilling system be used?Yes
Is H2S gas reasonably expected to be encountered during drilling operations at concentrations greater than
Noor equal to 100 ppm?
Will salt sections be encountered during drilling?No
Will salt based (>15,000 ppm Cl) drilling fluids be used?No
Will oil based drilling fluids be used?Yes
BOP Equipment Type:Annular Preventor Double Ram Rotating Head None
If yes, attach an H2S Drilling Plan unless a plan was already submitted with the Form 2A per Rule 304.c.(10).
Enter distance if less than or equal to 1,500 feet:239 No well belonging to another operator within 1,500 feetFeet
Will there be hydraulic fracture treatment at a depth less than 2,000 feet in this well?No
TVD at Proposed Total Measured Depth 7592 Feet
Page 4 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
Comments
OPERATOR COMMENTS AND SUBMITTAL
Casing Type Size of
Hole
Size of
Casing
Grade Wt/Ft Csg/Liner
Top
Setting
Depth
Sacks
Cmt
Cmt Btm Cmt Top
CONDUCTOR 26 16 ASTM
A53 B
36.94 0 80 64 80 0
SURF 12+1/4 8+5/8 L80 28 0 1761 580 1761 0
1ST 7+7/8 5+1/2 HCP110 17 0 20192 2297 20192 1000
Conductor Casing is NOT planned
CASING PROGRAM
POTENTIAL FLOW AND CONFINING FORMATIONS
Zone Type Formation
/Hazard
Top
M.D.
Top
T.V.D.
Bottom
M.D.
Bottom
T.V.D.
TDS
(mg/L)
Data Source Comment
Groundwater Fox Hills and
Shallower 17 17 539 539 501-1000 USGS Depth data from DWR
Confining Layer Pierre Shale 540 540 859 858
Groundwater Upper Pierre
Aquifer 860 859 1670 1650 1001-10000 Electric Log
Calculation Controlled by samples
Confining Layer Pierre Shale 1671 1651 4570 4480
Hydrocarbon Sussex 4571 4481 4808 4718 Productive
Confining Layer Pierre Shale 4809 4719 5153 5063
Hydrocarbon Shannon 5154 5064 5175 5085 Productive
Confining Layer Pierre Shale 5176 5086 7452 7330
Hydrocarbon Niobrara 7454 7331 8048 7607
Hydrocarbon Codell 8055 7608 20241 7634 Base MD/TVD is BHL per
ECMC
Page 5 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
Well name and API #:
• CLOVER 29-3HZ
• 05-123-52647
Explanation for need to sidetrack
• While drilling ahead in lateral, faulted from Fort Hays formation into the Carlile. Remained in Carlile formation due to
available LWD data and offset data indicating the Codell formation was being tracked appropriately. Later discovered
that the data being used to correlate our location in the reservoir was misleading and that we had entered the Carlile
and been drilling in the Carlile for 4500'. Due to lack of productivity in the Carlile, we will pull back and sidetrack a new
wellbore and remain in the Codell formation.
Total measured depth reached in the wellbore being plugged back
o 15,848’ MD
Casing set – size(s) and measured depth(s)
o 8.625” surface casing set at 1858’ MD
Description of fish in the hole (if any) – including top and bottom measured depths
o No fish left in hole.
Description of proposed plugs: setting measured depths, heights, and cement volumes
o Open hole sidetrack – no plugs are planned to be set
Type of cement to be used for all plugs, including slurry weight (ppg) and yield (cf/sk)
o Open hole sidetrack – no plugs are planned to be set
Measured depth of proposed sidetrack kick-off point
o 8850' MD
Proposed objective formation(s) for sidetrack hole – new or same as the wellbore being abandoned
o Same as original, permitted wellbore – Codell
BHL target for sidetrack hole – new or same as the wellbore being abandoned
o Same as original, permitted wellbore
MD different due to the directional profile of the well, and any change in the directional profile will likely change its MD to
some extent. The 20191’ MD is our final MD of the sidetrack wellbore.
This application is in a Comprehensive Area Plan
486289Location ID:
I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete.
Signed:Print Name:Christina Hirtler
Title:Regulatory Date:11/7/2024 Email:christina_hirtler@oxy.com
No CAP #:
Oil and Gas Development Plan Name SPROUT OGDP ID#:485787
Operator must have a valid water right or permit allowing for industrial use or purchased water from a seller that has a valid
water right or permit allowing for industrial use, otherwise an application for a change in type of use is required under Colorado
law. Operator must also use the water in the location set forth in the water right decree or well permit, otherwise an application
for a change in place of use is required under Colorado law. Section 37-92-103(5), C.R.S. (2011).
API NUMBER
05 123 52647 01
Expiration Date:03/05/2027
Based on the information provided herein, this Application for Permit-to-Drill complies with ECMC Rules, applicable orders, and
SB 19-181 and is hereby approved.
ECMC Approved:Director of ECMC Date:11/8/2024
Page 6 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
Best Management Practices
No BMP/COA Type Description
1 Drilling/Completion
Operations
Kerr-McGee acknowledges and will comply with the ECMC Policy for Bradenhead
Monitoring during Hydraulic Fracturing Treatments in the Greater Wattenberg Area
dated May 29, 2012.`
CONDITIONS OF APPROVAL, IF ANY LIST
All representations, stipulations and conditions of approval stated in the Form 2A for this location shall
constitute representations, stipulations and conditions of approval for this Form 2 Permit-to-Drill and are
enforceable to the same extent as all other representations, stipulations and conditions of approval stated in
this Permit-to-Drill.
COA Type Description
Drilling/Completion Operations Operator will log two (2) additional wells with open-hole resistivity log with gamma-ray
log from the kick-off point into the surface casing for the two stratigraphically deepest
wells on each side/direction of the pad for a total of three wells logged.
Drilling/Completion Operations Per Order 1-232, Bradenhead tests shall be performed according to the following
schedule and Form 17 submitted within 10 days of each test:
1) Within 60 days of rig release, prior to stimulation. If any pressure greater than 200 psi
is observed or if there is continuous flow, Operator must contact ECMC engineering for
approval prior to stimulation.
2) If a delayed completion, a second test is required between 6-9 months after rig
release and must be conducted prior to stimulation. If any pressure greater than 200 psi
is observed or if there is continuous flow, Operator must contact ECMC engineering for
approval prior to stimulation.
3) A post-production test within 60 days after first sales, as reported on the Form 10,
Certificate of Clearance.
Drilling/Completion Operations 1) Submit Form 42 electronically to ECMC 2 business days prior to MIRU (spud notice)
for the first well activity with a rig on the pad and provide 2 business day spud notice via
Form 42 for all subsequent wells drilled on the pad.
2) Comply with Rule 408.j. and provide cement coverage from TD to a minimum of 500'
above Niobrara and from 500’ below Sussex to 500’ above Sussex. Verify coverage
with a cement bond log.
3) Oil based drilling fluid can only be used after all groundwater has been isolated.
Drilling/Completion Operations Operator acknowledges the proximity of the listed wells. Operator agrees to: provide
mitigation option 1 or 2 (per the Offset Well Evaluation and Hydraulic Fracturing
Operator Guidance Document) to mitigate the situation, ensure all applicable
documentation is submitted based on the selected mitigation option chosen, and submit
a Form 42 (“OFFSET MITIGATION COMPLETED”) stating that appropriate mitigation
occurred and that it has been completed, prior to the hydraulic stimulation of this well.
05-123-11399 EMERSON #2-29 J
Drilling/Completion Operations Operator acknowledges the proximity of the listed wells. Operator assures that this
offset list will be remediated per the Offset Well Evaluation and Hydraulic Fracturing
Operator Guidance Document (option 4). Operator will submit a Form 42 (“OTHER- AS
SPECIFIED BY PERMIT CONDITION”) stating that appropriate mitigation will be
completed, during the hydraulic stimulation of this well. This Form 42 shall be filed 48
hours prior to stimulation. Surface and production casing pressures of this offset well list
will be actively monitored during stimulation of this well. If there is indication of
communication between the stimulation treatment and an offset well, treatment will be
stopped and ECMC Engineering notified.
05-123-48105 CARSON #1-6HZ
Drilling/Completion Operations Operator will log two (2) additional wells with open-hole resistivity log with gamma-ray
log from the kick-off point into the surface casing for the two stratigraphically deepest
wells on each side/direction of the pad for a total of three wells logged.
6 COAs
Page 7 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ
2 Drilling/Completion
Operations
Anti-Collision: Kerr-McGee will perform an anti-collision evaluation of all active
(producing, shut in, or temporarily abandoned) offset wellbores that have the potential
of being within one hundred fifty (150) feet of a proposed well prior to drilling
operations for the proposed well. Notice shall be given to all offset operators within one
hundred fifty (150) feet prior to drilling.`
3 Drilling/Completion
Operations
Alternative Logging Program: One of the first wells drilled on the pad will be logged
with open-hole resistivity log and gamma-ray log from the kick-off point into the surface
casing. All wells on the pad will have a cement bond log with gamma-ray run on
production casing (or on intermediate casing if production liner is run) into the surface
casing. The horizontal portion of every well will be logged with a measured-while
drilling gamma-ray log. The Form 5, Completion Report, for each well on the pad will
list all logs run and have those logs attached. The Form 5 for a well without open-hole
logs shall state “Alternative Logging Program - No open-hole logs were run” and shall
clearly identify the type of log and the well (by API#) in which open-hole logs were run.`
Total: 3 comment(s)
User Group Comment Comment Date
Approval With Operator concurrence corrected the MD/TVD depths for the BPZ, the setting depth
and cement bottom for the first string, and the proposed MD and TVD on the Drilling tab.
11/08/2024
Permit Final Review Completed. 11/07/2024
Permit Permitting review complete 11/07/2024
Permit Operator provided updated WBD - uploaded corrected and deleted incomplete document 11/06/2024
OGLA This Location and its associated Form 2A materials, and the Form 2 Application for
Permit to Drill were fully evaluated in accordance with current Rules and approved prior to
the commencement of drilling operations for this well. Because this is an application for
an unplanned sidetrack with drilling in progress, an Oil and Gas Location Assessment
review is not applicable to this ongoing operation. OGLA Task passed.
11/06/2024
OGLA Corrected Location ID to 486289.
Added OGDP ID 485787.
11/06/2024
Permit Corrected API number from -00 to -01 to represent sidetrack added BMP/COA information
Emailed operator for corrected / completed Wellbore Diagram - current one is incomplete
11/05/2024
Total: 7 comment(s)
General Comments
ATTACHMENT LIST
Att Doc Num Name
1517589 WELLBORE DIAGRAM
403983098 FORM 2 SUBMITTED
403983193 CORRESPONDENCE
403986186 DEVIATED DRILLING PLAN
403986188 DIRECTIONAL DATA
Total Attach: 5 Files
Page 8 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ