Loading...
HomeMy WebLinkAboutCLOVER 29-3HZ - Application for Permit-to-Drill - Kerr McGee - 11/8/2024State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 APPLICATION FOR PERMIT TO FORM 2 Rev 05/22 Document Number: 403983098 11/07/2024 Date Received: Well Plan: is Directional Horizontal (highly deviated) If Well plan is Directional or Horizontal attach Deviated Drilling Plan and Directional Data. X Vertical Subsurface Locations 67WRng:2NTwp:29Sec:Footage at TPZ:983 FNL FNL/FSL 1879 FWL FEL/FWL Top of Productive Zone (TPZ) Measured Depth of TPZ:8107 True Vertical Depth of TPZ:7610 WELL LOCATION INFORMATION FeetFeet -104.912088 QtrQtr:NWNE Sec:29 Rng:67W Twp:2N Meridian:6 Latitude:40.114871 Longitude: Footage at Surface:611 FNL FNL/FSL 1986 FEL FEL/FWL Field Name:WATTENBERG Field Number:90750 Ground Elevation:4996 GPS Data:Date of Measurement:05/02/2023GPS Quality Value:1.4 PDOPType of GPS Quality Value: Surface Location COMMINGLE ZONESMULTIPLE ZONESSINGLE ZONEZONE TYPE TYPE OF WELL OIL GAS COALBED OTHER:UNPLANNED SIDETRACK X X christina_hirtler@oxy.comEmail: Name of Operator:KERR MCGEE OIL & GAS ONSHORE LP ECMC Operator Number:47120 Address: P O BOX 173779 City:DENVER State:CO Zip:80217- 3779 Contact Name:Christina Hirtler Phone:(720)929-6301 Fax:( ) Well Number:29-3HZ Well Name:CLOVER FINANCIAL ASSURANCE FOR PLUGGING, ABANDONMENT, AND RECLAMATION Sidetrack Refile Amend X Drill Deepen Re-enter Recomplete and OperateX Federal Financial Assurance Amount of Federal Financial Assurance $ In checking this box, the Operator certifies that it has provided or will provide at least this amount of Financial Assurance to the federal government for this Well. (Per Rule702.a.) ECMC Financial Assurance The Operator has provided or will provide Financial Assurance to the ECMC for this Well.X Surety ID Number (if applicable):20230087 Page 1 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ SURFACE AND MINERAL OWNERSHIP AT WELL’S OIL & GAS LOCATION Surface Owner of the land at this Well’s Oil and Gas Location: Fee State Federal Indian Fee State Federal IndianMineral Owner beneath this Well’s Oil and Gas Location: Surface Owner Protection Bond (if applicable):Surety ID Number (if applicable): X X MINERALS DEVELOPED BY WELL The ownership of all the minerals that will be developed by this Well is (check all that apply): X Fee State Federal Indian N/A 68WRng:2NTwp:25Sec:142FNL FNL/FSL 1032 Bottom Hole Location (BHL) FWL FEL/FWL Footage at BHL: 68WRng:2NTwp:25Sec:Footage at BPZ:1032 FNL FNL/FSL 125 FWL FEL/FWL Base of Productive Zone (BPZ) Measured Depth of BPZ:20192 True Vertical Depth of BPZ:7592 LOCAL GOVERNMENT PERMITTING INFORMATION Per § 34-60-106(1)(f)(I)(A) C.R.S., the following questions pertain to the Relevant Local Government approval of the siting of the proposed Oil and Gas Location. SB 19-181 provides that when “applying for a permit to drill,” operators must include proof that they sought a local government siting permit and the disposition of that permit application, or that the local government does not have siting regulations. § 34-60-106(1)(f)(I) (A) C.R.S. County:WELD Municipality:N/A Does the Relevant Local Government regulate the siting of Oil and Gas Locations, with respect to this Location? If yes, in checking this box, I hereby certify that an application has been filed with the local government with jurisdiction to approve the siting of the proposed oil and gas location. NoYes ApprovedThe disposition of the application filed with the Relevant Local Government is: Comments:WOGLA#: 1041WOGLA23-0048 Is the Surface Location of this Well in an area designated as one of State interest and subject to the requirements of § Yes24-65.1-108 C.R.S.? X X Date of Final Disposition:01/26/2024 Page 2 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ LEASE INFORMATION Using standard QtrQtr, Section, Township, Range format describe one entire mineral lease as follows: * If this Well is within a unit, describe a lease that will be developed by the Well. * If this Well is not subject to a unit, describe the lease that will be produced by the Well. (Attach a Lease Map or Lease Description or Lease if necessary.) Township 1 North, Range 67 West, 6th P.M. Section 8: All Section 9: W/2, SE/4 Township 2 North, Range 67 West, 6th P.M. Section 19: All Section 30: SE/4 Section 32: W/2 Total Acres in Described Lease:2217 Described Mineral Lease is: Federal or State Lease # X Fee State Federal Indian Distance from Well to nearest: Building:2106 Feet Building Unit:2294 Feet Public Road:597 Feet Above Ground Utility:643 Feet Railroad:5280 Feet Property Line:611 Feet INSTRUCTIONS: - Specify all distances per Rule 308.b.(1). - Enter 5280 for distance greater than 1 mile. - Building - nearest building of any type. If nearest Building is a Building Unit, enter same distance for both. - Building Unit – as defined in 100 Series Rules. SAFETY SETBACK INFORMATION OBJECTIVE FORMATIONS Objective Formation(s)Formation Code Spacing Order Number(s)Unit Acreage Assigned to Well Unit Configuration (N/2, SE/4, etc.) CODELL CODL 407-3584 2400 T2N-67W;19:S2;20:SW;29:W2;30:ALL T2N-68W;24:S2;25:ALL Page 3 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ SPACING & FORMATIONS COMMENTS Federal or State Unit Name (if appl): Unit Number: SUBSURFACE MINERAL SETBACKS Enter 5280 for distance greater than 1 mile. Is this Well within a unit?Yes If YES: If NO: Enter the minimum distance from the Completed Zone of this Well to the Unit Boundary:125 Feet Feet434 Enter the minimum distance from the Completed Zone of this Well to the Completed Zone of an offset Well within the same unit permitted or completed in the same formation: Enter the minimum distance from the Completed Zone of this Well to the Lease Line of the described lease:Feet Feet Enter the minimum distance from the Completed Zone of this Well to the Completed Zone of an offset Well producing from the same lease and permitted or completed in the same formation: Exception Location If this Well requires the approval of a Rule 401.c Exception Location, enter the Rule or spacing order number and attach the Exception Location Request and Waivers. Beneficial reuse or land application plan submitted?Yes Reuse Facility ID:or Document Number: DRILLING PROGRAM Proposed Total Measured Depth:20192 Feet Distance from the proposed wellbore to nearest existing or proposed wellbore belonging to another operator, including plugged wells: Will a closed-loop drilling system be used?Yes Is H2S gas reasonably expected to be encountered during drilling operations at concentrations greater than Noor equal to 100 ppm? Will salt sections be encountered during drilling?No Will salt based (>15,000 ppm Cl) drilling fluids be used?No Will oil based drilling fluids be used?Yes BOP Equipment Type:Annular Preventor Double Ram Rotating Head None If yes, attach an H2S Drilling Plan unless a plan was already submitted with the Form 2A per Rule 304.c.(10). Enter distance if less than or equal to 1,500 feet:239 No well belonging to another operator within 1,500 feetFeet Will there be hydraulic fracture treatment at a depth less than 2,000 feet in this well?No TVD at Proposed Total Measured Depth 7592 Feet Page 4 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ Comments OPERATOR COMMENTS AND SUBMITTAL Casing Type Size of Hole Size of Casing Grade Wt/Ft Csg/Liner Top Setting Depth Sacks Cmt Cmt Btm Cmt Top CONDUCTOR 26 16 ASTM A53 B 36.94 0 80 64 80 0 SURF 12+1/4 8+5/8 L80 28 0 1761 580 1761 0 1ST 7+7/8 5+1/2 HCP110 17 0 20192 2297 20192 1000 Conductor Casing is NOT planned CASING PROGRAM POTENTIAL FLOW AND CONFINING FORMATIONS Zone Type Formation /Hazard Top M.D. Top T.V.D. Bottom M.D. Bottom T.V.D. TDS (mg/L) Data Source Comment Groundwater Fox Hills and Shallower 17 17 539 539 501-1000 USGS Depth data from DWR Confining Layer Pierre Shale 540 540 859 858 Groundwater Upper Pierre Aquifer 860 859 1670 1650 1001-10000 Electric Log Calculation Controlled by samples Confining Layer Pierre Shale 1671 1651 4570 4480 Hydrocarbon Sussex 4571 4481 4808 4718 Productive Confining Layer Pierre Shale 4809 4719 5153 5063 Hydrocarbon Shannon 5154 5064 5175 5085 Productive Confining Layer Pierre Shale 5176 5086 7452 7330 Hydrocarbon Niobrara 7454 7331 8048 7607 Hydrocarbon Codell 8055 7608 20241 7634 Base MD/TVD is BHL per ECMC Page 5 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ Well name and API #: • CLOVER 29-3HZ • 05-123-52647 Explanation for need to sidetrack • While drilling ahead in lateral, faulted from Fort Hays formation into the Carlile. Remained in Carlile formation due to available LWD data and offset data indicating the Codell formation was being tracked appropriately. Later discovered that the data being used to correlate our location in the reservoir was misleading and that we had entered the Carlile and been drilling in the Carlile for 4500'. Due to lack of productivity in the Carlile, we will pull back and sidetrack a new wellbore and remain in the Codell formation. Total measured depth reached in the wellbore being plugged back o 15,848’ MD Casing set – size(s) and measured depth(s) o 8.625” surface casing set at 1858’ MD Description of fish in the hole (if any) – including top and bottom measured depths o No fish left in hole. Description of proposed plugs: setting measured depths, heights, and cement volumes o Open hole sidetrack – no plugs are planned to be set Type of cement to be used for all plugs, including slurry weight (ppg) and yield (cf/sk) o Open hole sidetrack – no plugs are planned to be set Measured depth of proposed sidetrack kick-off point o 8850' MD Proposed objective formation(s) for sidetrack hole – new or same as the wellbore being abandoned o Same as original, permitted wellbore – Codell BHL target for sidetrack hole – new or same as the wellbore being abandoned o Same as original, permitted wellbore MD different due to the directional profile of the well, and any change in the directional profile will likely change its MD to some extent. The 20191’ MD is our final MD of the sidetrack wellbore. This application is in a Comprehensive Area Plan 486289Location ID: I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete. Signed:Print Name:Christina Hirtler Title:Regulatory Date:11/7/2024 Email:christina_hirtler@oxy.com No CAP #: Oil and Gas Development Plan Name SPROUT OGDP ID#:485787 Operator must have a valid water right or permit allowing for industrial use or purchased water from a seller that has a valid water right or permit allowing for industrial use, otherwise an application for a change in type of use is required under Colorado law. Operator must also use the water in the location set forth in the water right decree or well permit, otherwise an application for a change in place of use is required under Colorado law. Section 37-92-103(5), C.R.S. (2011). API NUMBER 05 123 52647 01 Expiration Date:03/05/2027 Based on the information provided herein, this Application for Permit-to-Drill complies with ECMC Rules, applicable orders, and SB 19-181 and is hereby approved. ECMC Approved:Director of ECMC Date:11/8/2024 Page 6 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ Best Management Practices No BMP/COA Type Description 1 Drilling/Completion Operations Kerr-McGee acknowledges and will comply with the ECMC Policy for Bradenhead Monitoring during Hydraulic Fracturing Treatments in the Greater Wattenberg Area dated May 29, 2012.` CONDITIONS OF APPROVAL, IF ANY LIST All representations, stipulations and conditions of approval stated in the Form 2A for this location shall constitute representations, stipulations and conditions of approval for this Form 2 Permit-to-Drill and are enforceable to the same extent as all other representations, stipulations and conditions of approval stated in this Permit-to-Drill. COA Type Description Drilling/Completion Operations Operator will log two (2) additional wells with open-hole resistivity log with gamma-ray log from the kick-off point into the surface casing for the two stratigraphically deepest wells on each side/direction of the pad for a total of three wells logged. Drilling/Completion Operations Per Order 1-232, Bradenhead tests shall be performed according to the following schedule and Form 17 submitted within 10 days of each test: 1) Within 60 days of rig release, prior to stimulation. If any pressure greater than 200 psi is observed or if there is continuous flow, Operator must contact ECMC engineering for approval prior to stimulation. 2) If a delayed completion, a second test is required between 6-9 months after rig release and must be conducted prior to stimulation. If any pressure greater than 200 psi is observed or if there is continuous flow, Operator must contact ECMC engineering for approval prior to stimulation. 3) A post-production test within 60 days after first sales, as reported on the Form 10, Certificate of Clearance. Drilling/Completion Operations 1) Submit Form 42 electronically to ECMC 2 business days prior to MIRU (spud notice) for the first well activity with a rig on the pad and provide 2 business day spud notice via Form 42 for all subsequent wells drilled on the pad. 2) Comply with Rule 408.j. and provide cement coverage from TD to a minimum of 500' above Niobrara and from 500’ below Sussex to 500’ above Sussex. Verify coverage with a cement bond log. 3) Oil based drilling fluid can only be used after all groundwater has been isolated. Drilling/Completion Operations Operator acknowledges the proximity of the listed wells. Operator agrees to: provide mitigation option 1 or 2 (per the Offset Well Evaluation and Hydraulic Fracturing Operator Guidance Document) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OFFSET MITIGATION COMPLETED”) stating that appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well. 05-123-11399 EMERSON #2-29 J Drilling/Completion Operations Operator acknowledges the proximity of the listed wells. Operator assures that this offset list will be remediated per the Offset Well Evaluation and Hydraulic Fracturing Operator Guidance Document (option 4). Operator will submit a Form 42 (“OTHER- AS SPECIFIED BY PERMIT CONDITION”) stating that appropriate mitigation will be completed, during the hydraulic stimulation of this well. This Form 42 shall be filed 48 hours prior to stimulation. Surface and production casing pressures of this offset well list will be actively monitored during stimulation of this well. If there is indication of communication between the stimulation treatment and an offset well, treatment will be stopped and ECMC Engineering notified. 05-123-48105 CARSON #1-6HZ Drilling/Completion Operations Operator will log two (2) additional wells with open-hole resistivity log with gamma-ray log from the kick-off point into the surface casing for the two stratigraphically deepest wells on each side/direction of the pad for a total of three wells logged. 6 COAs Page 7 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ 2 Drilling/Completion Operations Anti-Collision: Kerr-McGee will perform an anti-collision evaluation of all active (producing, shut in, or temporarily abandoned) offset wellbores that have the potential of being within one hundred fifty (150) feet of a proposed well prior to drilling operations for the proposed well. Notice shall be given to all offset operators within one hundred fifty (150) feet prior to drilling.` 3 Drilling/Completion Operations Alternative Logging Program: One of the first wells drilled on the pad will be logged with open-hole resistivity log and gamma-ray log from the kick-off point into the surface casing. All wells on the pad will have a cement bond log with gamma-ray run on production casing (or on intermediate casing if production liner is run) into the surface casing. The horizontal portion of every well will be logged with a measured-while drilling gamma-ray log. The Form 5, Completion Report, for each well on the pad will list all logs run and have those logs attached. The Form 5 for a well without open-hole logs shall state “Alternative Logging Program - No open-hole logs were run” and shall clearly identify the type of log and the well (by API#) in which open-hole logs were run.` Total: 3 comment(s) User Group Comment Comment Date Approval With Operator concurrence corrected the MD/TVD depths for the BPZ, the setting depth and cement bottom for the first string, and the proposed MD and TVD on the Drilling tab. 11/08/2024 Permit Final Review Completed. 11/07/2024 Permit Permitting review complete 11/07/2024 Permit Operator provided updated WBD - uploaded corrected and deleted incomplete document 11/06/2024 OGLA This Location and its associated Form 2A materials, and the Form 2 Application for Permit to Drill were fully evaluated in accordance with current Rules and approved prior to the commencement of drilling operations for this well. Because this is an application for an unplanned sidetrack with drilling in progress, an Oil and Gas Location Assessment review is not applicable to this ongoing operation. OGLA Task passed. 11/06/2024 OGLA Corrected Location ID to 486289. Added OGDP ID 485787. 11/06/2024 Permit Corrected API number from -00 to -01 to represent sidetrack added BMP/COA information Emailed operator for corrected / completed Wellbore Diagram - current one is incomplete 11/05/2024 Total: 7 comment(s) General Comments ATTACHMENT LIST Att Doc Num Name 1517589 WELLBORE DIAGRAM 403983098 FORM 2 SUBMITTED 403983193 CORRESPONDENCE 403986186 DEVIATED DRILLING PLAN 403986188 DIRECTIONAL DATA Total Attach: 5 Files Page 8 of 8Date Run: 11/8/2024 Doc [#403983098] Well Name: CLOVER 29-3HZ