Loading...
HomeMy WebLinkAboutCOORS V 6-13 - Well Abandonment Report - Kerr McGee - 8/1/2018Status VISU0578SURF 12+1/4 8+5/8 24 578 400 CBL6,7777,4931ST 7+7/8 3+1/2 7.7 7,493 370 CBL3,5354,862S.C. 1.1 7,493 151 Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement TopCement Bot Casing History Subsequent Report of Abandonment Details: If yes, explain details below If yes, explain details below Yes NoWellbore has Uncemented Casing leaks: NoYesFish in Hole: 860Estimated Depth:NoYesCasing to be pulled: Other Mechanical ProblemsProduction Sub-economicDryReason for Abandonment: -104.93966440.162479 Longitude: GPS Data: Only Complete the Following Background Information for Intent to Abandon ROB WILSON1.805/10/2017 GPS Instrument Operator's Name:PDOP Reading:Date of Measurement: Latitude: 90750Field Number:Field Name:WATTENBERG Federal, Indian or State Lease Number: Meridian:667W Range:Township:2N 6 Section:QtrQtr: 6-13 Well Number: SWSW County:WELD Location: COORS VWell Name: 05-123-17323-00API Number This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete, this form shall again be submitted as a Subsequent Report of the actual work completed. The approved intent shall be valid for six months after the approval date, after that period, a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration and the proposed configuration with plugs set. A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellbore diagram showing plugs that were set and casing remaining in the hole, the job summaries from all plugging contractors used, including wireline and cementing (third party verification) and any logs that may have been run during abandonment. State of Colorado Oil and Gas Conservation Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 WELL ABANDONMENT REPORT FORM 6 Rev 05/18 Notice of Intent to Abandon cheryl.light@anadarko.comEmail: (720) 929-7461Fax: (720) 929-6461Phone: Zip:80217- 3779 COState:DENVER P O BOX 173779 Contact Name: City: CHERYL LIGHT Address: KERR MCGEE OIL & GAS ONSHORE LPName of Operator: 47120OGCC Operator Number: tom.beardslee@state.co.usEmail: Tel:(970) 420-3935Name:Beardslee, Tom For "Intent" 24 hour notice required, COGCC contact: 08/01/2018 Date Received: Document Number: DE ET OE ES 401697090 Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth CODELL 7348 7364 Total: 1 zone(s) Current and Previously Abandoned Zones Page 1 of 3Date Run: 8/1/2018 Doc [#401697090] Well Name: COORS V 6-13 *ATTACH JOB SUMMARY Technical Detail/Comments: 1/31/2019Expiration Date: NoYesFlowline/Pipeline has been abandoned per Rule 1105 Type of Cement and Additives Used: *Cementing Contractor: *Wireline Contractor: Plugging Date:inch casingft. of Additional Plugging Information for Subsequent Report Only Casing Recovered: Plug Tagged: Plug Type: Plug Tagged: Plug Type: Plug Tagged: Plug Type: Plug Tagged: Plug Type: Plug Tagged:CASING Plug Tagged: (Cast Iron Cement Retainer Depth) CICR Depth CICR Depth CICR Depth sacks cmt on top.withCIBP #5: Depth sacks cmt on top.withsacks cmt on top. CIPB #4: Depth25with80CIBP #3: Depth Set sacks in mouse holeSetsacks in rat hole NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate 25Set sacks at surface ft.528ft. to960sacks half in. half out surface casing fromSet215 sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at sacks. Leave at least 100 ft. in casingft. withPerforate and squeeze at ft. ft. tosks cmt fromSet ft. ft. tosks cmt fromSet ft. ft. tosks cmt fromSet ft. ft. tosks cmt fromSet ft. 6620ft. to7290sks cmt from25Set sacks cmt on top.3900 with 2sacks cmt on top. CIPB #2: Depth25with7290CIBP #1: Depth Plug Type: NOTE: Two(2) sacks cement required on all CIBPs. Plugging Procedure for Intent and Subsequent Report McCoy, Diane Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable orders and is hereby approved. COGCC Approved:Date:8/1/2018 I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete. Signed:Print Name:CHERYL LIGHT Title:Staff Regulatory Analyst Date:8/1/2018 Email:DJREGULATORY@ANADARKO.COM CONDITIONS OF APPROVAL, IF ANY: Page 2 of 3Date Run: 8/1/2018 Doc [#401697090] Well Name: COORS V 6-13 COA Type Description 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) Properly abandon on-location flowlines per Rule 1105. File electronic Form 42 once abandonment complete. Within 30 days of an operator completing abandonment requirements for an off-location flowline or crude oil transfer line the operator must submit a Flowline Report, Form 44. 3) Operator shall implement measures to control unnecessary and excessive venting, to protect the health and safety of the public, and to ensure that vapors and odors from well plugging operations do not constitute a nuisance or hazard to public welfare. 4) Production casing stub plug is also surface casing shoe plug, this plug must be tagged at 528’ or shallower. Prior to starting plugging operations a bradenhead test shall be performed if there has not been a reported bradenhead test within the 60 days immediately preceding the start of plugging operations. 1) If, before opening the bradenhead valve, the beginning pressure is greater than 25 psi, sampling is required. 2) If pressure remains at the conclusion of the test, or if any liquids were present during the test, sampling is required. The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are collected, copies of all final laboratory analytical results shall be provided to the COGCC within three (3) months of collecting the samples. If there is a need for sampling, contact COGCC engineering for verification of plugging procedure. Attachment Check List Att Doc Num Name 401697090 WELL ABANDONMENT REPORT (INTENT) 401720887 PROPOSED PLUGGING PROCEDURE 401720888 WELLBORE DIAGRAM 401721291 FORM 6 INTENT SUBMITTED Total Attach: 4 Files User Group Comment Comment Date Engineer Wellbore diagram shows bottom of stage cement at 4840’ but it was listed as 4862’ on this form; see CBL doc #83954. on hold- Emailed operator about proposed squeeze. Pushed form back to draft to allow operator to make edits. 07/31/2018 Permit Removed COA and passed form 4 with new GPS coordinates and entered information into this form. 07/18/2018 Well File Verification Pass 07/12/2018 Total: 3 comment(s) General Comments Page 3 of 3Date Run: 8/1/2018 Doc [#401697090] Well Name: COORS V 6-13