Loading...
HomeMy WebLinkAboutVARRA 20-32 - Off Location Flowline - Kerr McGee - 2/22/2019State of Colorado Oil and Gas Conservation Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 Off-Location Flowline FORM 44 Rev 03/18 Document Number: OGCC RECEPTION Receive Date: 02/22/2019 The Flowline Report, Form 44, shall be submitted to register, report realignment, report removal from service, or report abandonment of Off-Location Flowlines , Produced Water Transfer Systems, Domestic Taps, or Crude Oil Transfer Lines as required by the 1100 Series Rules. The Form shall also be submitted to report Grade 1 Gas Leaks from Flowlines per Rule 1104.k. 401949119 OFF LOCATION FLOWLINE FLOWLINE ENDPOINT LOCATION IDENTIFICATION Location ID:330474 Location Type:Production Facilities Name:VARRA Number:20-32 County:WELD Qtr Qtr:SESE Section:32 Township:3N Range:67W Meridian:6 Latitude:40.176394 Longitude:-104.906000 FLOWLINE FACILITY INFORMATION Flowline Facility ID:462334 Flowline Type:Wellhead Line Action Type:Abandonment OFF LOCATION FLOWLINE REGISTRATION Flowline End Point Riser Latitude:40.175443 Longitude:-104.905846 PDOP:1.3 Measurement Date:08/08/2017 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:330474 Location Type:Well Site Name:VARRA Number:20-32 County:WELD Qtr Qtr:SESE Section:32 Township:3N Range:67W Meridian:6 Latitude:40.176394 Longitude:-104.906000 Flowline Start Point Riser Latitude:40.176278 Longitude : -104.906035 PDOP:1.5 Measurement Date:08/08/2017 Equipment at Start Point Riser:Well No Location ID OGCC Operator Number: City: Company Name: Address: 47120 KERR MCGEE OIL & GAS ONSHORE LP P O BOX 173779 DENVER Zip:State:80217-3779 Contact Person:Mike Holle Phone:(720) 9296639 CO Email:mike.holle@anadarko.com Is the Operator a Tier One member of the Utility Notification Center of Colorado (UNCC) that participates in Colorado's One Call notification system?Yes No Operator Information Date Run: 2/22/2019 Doc [#401949119]Page 1 of 4 Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:03/22/2011 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE ABANDONMENT Date:11/26/2018 Description of Abandonment The Varra 20-32 P&A is complete. The well head was cut and capped on 11/16/2018. The entire flow line was removed on 11/26/2018. FLOWLINE FACILITY INFORMATION Flowline Facility ID:459302 Flowline Type:Wellhead Line Action Type: OFF LOCATION FLOWLINE REGISTRATION Flowline End Point Riser Latitude:40.175383 Longitude:-104.905848 PDOP:1.5 Measurement Date:08/15/2017 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:330473 Location Type:Well Site Name:HSR-HEINTZELMAN-63N67W Number:32NESE County:WELD Qtr Qtr:NESE Section:32 Township:3N Range:67W Meridian:6 Latitude:40.179981 Longitude:-104.905958 Flowline Start Point Riser Latitude:40.179991 Longitude : -104.905955 PDOP:1.5 Measurement Date:08/08/2017 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:12/17/2004 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE REMOVAL FROM SERVICE Date:09/18/2018 Description of Removal from Service The HSR-Heintzelman 9-32 P&A is complete. The well head was cut and capped on 9/10/2018. The entire flow line was removed on 9/18/2018. The separator was also removed on 9/18/2018. HSR-HEINTZELMAN 9-32 05-123-19164 FL-HSR-HEINTZELMAN 9-32 No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:457408 Flowline Type:Wellhead Line Action Type:Abandonment OFF LOCATION FLOWLINE REGISTRATION Date Run: 2/22/2019 Doc [#401949119]Page 2 of 4 Flowline End Point Riser Latitude:40.175436 Longitude:-104.905832 PDOP:1.4 Measurement Date:08/08/2017 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:330474 Location Type:Well Site Name:VARRA Number:20-32 County:WELD Qtr Qtr:SESE Section:32 Township:3N Range:67W Meridian:6 Latitude:40.176394 Longitude:-104.906000 Flowline Start Point Riser Latitude:40.176274 Longitude : -104.905978 PDOP:1.3 Measurement Date:08/08/2017 Equipment at Start Point Riser:Well Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:03/22/2011 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE ABANDONMENT Date:11/25/2018 Description of Abandonment The Varra 39-32 P&A is complete. The well head was cut and capped on 11/16/2018. The entire flow line was removed on 11/25/2018. The entire tank battery was removed on 11/28/2018. No Location ID FLOWLINE FACILITY INFORMATION Flowline Facility ID:462335 Flowline Type:Wellhead Line Action Type:Abandonment OFF LOCATION FLOWLINE REGISTRATION Flowline End Point Riser Latitude:40.175442 Longitude:-104.905854 PDOP:1.3 Measurement Date:08/08/2017 Equipment at End Point Riser:Separator Flowline Start Point Location Identification Location ID:330474 Location Type:Well Site Name:VARRA Number:20-32 County:WELD Qtr Qtr:SESE Section:32 Township:3N Range:67W Meridian:6 Latitude:40.176394 Longitude:-104.906000 Flowline Start Point Riser Latitude:40.176280 Longitude : -104.906089 PDOP:1.5 Measurement Date:08/08/2017 Equipment at Start Point Riser:Well No Location ID Date Run: 2/22/2019 Doc [#401949119]Page 3 of 4 Flowline Description and Testing Type of Fluid Transferred:Pipe Material:Max Outer Diameter:(Inches) Bedding Material:Date Construction Completed:03/22/2011 Maximum Anticipated Operating Pressure (PSI):Testing PSI: Test Date: OFF LOCATION FLOWLINE ABANDONMENT Date:11/29/2018 Description of Abandonment The Varra 37-32x P&A is complete. The well head was cut and capped on 11/16/2018. The entire flow line was removed on 11/29/2018. mike.holle@anadarko.com SDA 02/22/2019 Mike Holle COGCC Approved:Director of COGCC Date: Based on the information provided herein, this Flowline Report complies with COGCC Rules and applicable orders and is hereby approved. Title: Email:Date: Print Name: Signed: I hereby certify that the statements made in this form are, to the best of my knowledge, true, correct and complete. The Varra 39-32 P&A is complete. The well head was cut and capped on 11/16/2018. The entire flow line was removed on 11/25/2018. The entire tank battery was removed on 11/28/2018. The Varra 37-32x P&A is complete. The well head was cut and capped on 11/16/2018. The entire flow line was removed on 11/29/2018. The Varra 20-32 P&A is complete. The well head was cut and capped on 11/16/2018. The entire flow line was removed on 11/26/2018. Comments OPERATOR COMMENTS AND SUBMITTAL Attachment Check List Att Doc Num Name Total Attach: 0 Files Date Run: 2/22/2019 Doc [#401949119]Page 4 of 4