HomeMy WebLinkAboutROCKY MTN FUEL V 19-5JI - Well Abandonment Report - Kerr McGee - 11/9/2023Casing History
Subsequent Report of Abandonment
Details:
If yes, explain details below
If yes, explain details below
Yes NoWellbore has Uncemented Casing leaks:
NoYesFish in Hole:
895Estimated Depth:NoYesCasing to be pulled:
Other
Mechanical ProblemsProduction Sub-economicDryReason for Abandonment:
-104.93636040.125680 Longitude:
GPS Data:
Only Complete the Following Background Information for Intent to Abandon
2.9 06/20/2007GPS Quality Value:Date of Measurement:
Latitude:
Type of GPS Quality Value:
90750Field Number:Field Name:WATTENBERG
Federal, Indian or State Lease Number:
Meridian:667W Range:Township:2N 19Section:QtrQtr:
19-5JI Well Number:
SENW
County:WELD
Location:
ROCKY MTN FUEL VWell Name:
05-123-20217-00API Number
This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the
abandonment is complete, this form shall again be submitted as a Subsequent Report of the actual work completed. The
approved intent shall be valid for six months after the approval date, after that period, a new intent will be required.
Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration and the proposed
configuration with plugs set.
A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent
Report are a wellbore diagram showing plugs that were set and casing remaining in the hole, the job summaries from all
plugging contractors used, including wireline and cementing (third party verification) and any logs that may have been run
during abandonment.
State of Colorado
Oil and Gas Conservation Commission
1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894
-2109
WELL ABANDONMENT REPORT
FORM
6
Rev
11/20
Notice of Intent to Abandon
Lindsay_Davis@oxy.comEmail:
Fax:
(970) 515-1616Phone:
Zip:80217-
3779
COState:DENVER
P O BOX 173779
Contact Name:
City:
Lindsay Davis
Address:
KERR MCGEE OIL & GAS ONSHORE LPName of Operator:
47120OGCC Operator Number:
robbie.revas@state.co.usEmail:
Tel:(720) 661-7242Name:Revas, Robbie For "Intent" 24 hour notice required,
COGCC contact:
06/02/2023
Date Received:
Document Number:
DE ET OE ES
403421115
Formation Perf. Top Perf. Btm Abandoned Date Method of Isolation Plug Depth
CODELL 7717 7734
J SAND 8154 8190
Total: 2 zone(s)
Current and Previously Abandoned Zones
Type of Well Abandonment Report:
Page 1 of 5Date Run: 6/15/2023 Doc [#403421115] Well Name: ROCKY MTN FUEL V 19-5JI
Technical Detail/Comments:
NoYesFlowline/Pipeline has been abandoned per Rule 1105
Type of Cement and Additives Used:
*Cementing Contractor: *Wireline Contractor:
Cut and Cap Date:
inch casingft. of
Additional Plugging Information for Subsequent Report Only
Casing Recovered:
Plug Tagged:CASINGPlug Type:
Plug Tagged:CASINGPlug Type:
Plug Tagged:CASINGPlug Type:
Plug Tagged:CASINGPlug Type:
Plug Tagged:CASING
Plug Tagged:
(Cast Iron Cement Retainer Depth)
CICR Depth
CICR Depth
2610
4290
CICR Depth7430
sacks cmt on top.withCIBP #5: Depth
sacks cmt on top.withsacks cmt on top. CIBP #4: DepthwithCIBP #3: Depth
Set sacks in mouse holeSetsacks in rat hole
NoYesAbove Ground Dry-Hole Marker:Cut four feet below ground level, weld on plate
80Set sacks at surface
ft.742ft. to895sacks half in. half out surface casing fromSet120
sacks. Leave at least 100 ft. in casing215ft. with2800Perforate and squeeze at
sacks. Leave at least 100 ft. in casing85ft. with4350Perforate and squeeze at
sacks. Leave at least 100 ft. in casing100ft. withPerforate and squeeze at 7490
ft. 0ft. to260sks cmt fromSet80
ft. 950ft. to1210sks cmt fromSet20
ft. 1960ft. to2160sks cmt fromSet15
ft. 4090ft. to4290sks cmt fromSet15
ft. 7170ft. to7430sks cmt from15Set
sacks cmt on top.260 with 80sacks cmt on top. CIBP #2: Depth2with8170CIBP #1: Depth
Plug Type:
NOTE: Two(2) sacks cement
required on all CIBPs.
Plugging Procedure for Intent and Subsequent Report
Casing Type Size of
Hole
Size of
Casing
Grade Wt/Ft Csg/Liner
Top
Setting
Depth
Sacks Cmt Cmt Btm Cmt Top Status
SURF 12+1/4 8+5/8 J-55 24 0 792 555 792 0 VISU
1ST 7+7/8 4+1/2 L-80 11.6 0 8349 210 8349 6954 CBL
7+7/8 4+1/2 L-80 Stage
Tool
0 8349 220 5134 3802 CBL
Surface Plug Setting Date:
Number of Days from Setting Surface Plug
to Capping or Sealing the Well:
Page 2 of 5Date Run: 6/15/2023 Doc [#403421115] Well Name: ROCKY MTN FUEL V 19-5JI
12/14/2023Expiration Date:
Perforate and squeeze at 1800 ft. with 210 sacks. Leave at least 100 ft. in casing 1210 CICR Depth (Cast Iron Cement Retainer)
BMPs
Signage for P&As:
Prior to commencing operations, KMG will post signs in conspicuous locations. The signs will indicate plugging and abandonment
operations are being conducted, the well name, well, and the Operator’s contact information. Signs will be placed so as not to create
a potential traffic hazard.
Notifications:
Courtesy notifications will be sent to all parcel owners with building units within 1,500 feet of the location letting them know about out
plugging and abandonment operations and providing contact information for Kerr McGee's response line and online resources.
Wellbore Pressure:
In some cases, wellbore pressure drawdown operations may occur approximately 1-2 days prior to Move In Rig Up (MIRU) of the
workover rig. This is conducted to allow for reduced time that the workover rig is needed on location. These operations will be
conducted in accordance with Form 4 and/or Form 6 requirements.
Water:
Water will be placed on dirt access roads to mitigate dust as needed.
Lighting:
Operations are daylight-only; no lighting impacts are anticipated from operations.
Noise:
Operations will be in compliance with Table 423-1 requirements. Based off the rig sound signature, rig orientation will be considered
to reduce noise levels to nearby building units.
Environmental Concerns:
This location was reviewed using a desktop method to review publicly available wildlife data (including CPW & COGCC data) as well
as internal wildlife datasets and aerial imagery. All field personnel are trained to identify wildlife risks and raise concerns noticed
during operations with the KMOG Health, Safety, and Environment (HSE) department.
COA Type Description
Consistent with Rule 911.a, a Form 27 must be approved prior to cut and cap,
conducting flowline abandonment, or removing production equipment. Allow 30 days for
Director review of the Form 27; include the Form 27 document number on the Form 44
for offsite flowline abandonment (if applicable) and on the Form 6 Subsequent.
Properly abandon flowlines per Rule 1105. If flowlines will be abandoned in place,
include with the Form 27: pressure test results conducted in the prior 12 months as well
as identification of any document numbers for a COGCC Spill/Release Report, Form
19, associated with the abandoned line.
Haverkamp, Curtis
Based on the information provided herein, this Well Abandonment Report (Form 6) complies with COGCC Rules and applicable
orders and is hereby approved.
COGCC Approved:Date:6/15/2023
I hereby certify all statements made in this form are, to the best of my knowledge, true, correct, and complete.
Signed:Print Name:Lindsay Davis
Title:Regulatory Tech Date:6/2/2023 Email:Lindsay_Davis@oxy.com
CONDITIONS OF APPROVAL, IF ANY:
Page 3 of 5Date Run: 6/15/2023 Doc [#403421115] Well Name: ROCKY MTN FUEL V 19-5JI
1) Provide electronic Form 42 Notice of MIRU 2 business days ahead of operations and
electronic Form 42 Notice of Plugging Operations 48 hours prior to mobilizing for
plugging operations. These are two separate notifications, required by Rules 405.e and
405.l.
2) After placing plug at 2800’ assure that all fluid migration has been eliminated by
monitoring the well for a minimum of 8 hours before proceeding to the next plug. If at
any time after placing this plug there is evidence of pressure or of fluid migration,
contact COGCC engineering before continuing operations.
3) Prior to placing cement above the base of the Upper Pierre (approximately 1474’):
verify that all fluid (liquid and gas) migration has been eliminated. If evidence of fluid
migration or pressure remains, contact COGCC Engineer for an update to plugging
orders.
4) If surface casing shoe plug is not circulated to surface, shut-in, WOC 4 hours then
tag plug – must be at 742’ or shallower and provide a minimum of 10 sx plug at the
surface.
5) Leave at least 100’ of cement in the wellbore for each plug without mechanical
isolation.
6) With the Form 6 SRA operator must provide written documentation which positively
affirms each COA listed above has been addressed.
Prior to starting plugging operations a bradenhead test shall be performed if there has
not been a reported bradenhead test within the 60 days immediately preceding the start
of plugging operations.
1) If, before opening the bradenhead valve, the beginning pressure is greater than 25
psi, sampling is required.
2) If pressure remains at the conclusion of the test, or if any liquids were present during
the test, sampling is required.
The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with
Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are
collected, copies of all final laboratory analytical results shall be provided to the COGCC
within three (3) months of collecting the samples.
If there is a need for sampling, contact COGCC engineering for verification of plugging
procedure.
Due to proximity to a mapped wetland and surface water, operator will use secondary
containment for all tanks and other liquid containers. Operator will implement
stormwater BMPs and erosion control measures as needed to prevent sediment and
stormwater runoff from entering the wetland and surface water.
COA's provided by the operator as Best Management Practices under Technical Detail /
Comments:
Signage for P&As:
Prior to commencing operations, KMG will post signs in conspicuous locations. The
signs will indicate plugging and abandonment operations are being conducted, the well
name, well, and the Operator’s contact information. Signs will be placed so as not to
create a potential traffic hazard.
Notifications:
Courtesy notifications will be sent to all parcel owners with building units within 1,500
feet of the location letting them know about out plugging and abandonment operations
and providing contact information for Kerr McGee's response line and online resources.
Noise:
Operations will be in compliance with Table 423-1 requirements. Based off the rig
sound signature, rig orientation will be considered to reduce noise levels to nearby
building units.
5 COAs
Page 4 of 5Date Run: 6/15/2023 Doc [#403421115] Well Name: ROCKY MTN FUEL V 19-5JI
Attachment List
Att Doc Num Name
403421115 WELL ABANDONMENT REPORT (INTENT)
403421178 PROPOSED PLUGGING PROCEDURE
403421179 WELLBORE DIAGRAM
403434697 FORM 6 INTENT SUBMITTED
Total Attach: 4 Files
User Group Comment Comment Date
Engineer DWR base of Fox Hills: 359'
Deepest water well within 1 mile: 730'
Base of Upper Pierre estimated: 1474'
Bradenhead history: 14 psi (7/20/2022)
06/15/2023
OGLA OGLA review complete.06/12/2023
Permit Confirmed as-drilled well location.
No other forms in process.
Confirmed productive intervals Docnum: 1967725.
Production reporting up-to-date for this operator.
Reviewed procedure and WBD.
Pass.
06/06/2023
Total: 3 comment(s)
General Comments
Page 5 of 5Date Run: 6/15/2023 Doc [#403421115] Well Name: ROCKY MTN FUEL V 19-5JI