Loading...
HomeMy WebLinkAboutBUTTERBALL TANK BATTERY 25C-34HZ - Other - Kerr McGee - 2/25/2025CONTACT INFORMATION Initial Notice of Accident State of Colorado Energy & Carbon Management Commission 1120 Lincoln Street, Suite 801, Denver, Colorado 80203 Phone: (303) 894-2100 Fax: (303) 894-2109 ACCIDENT REPORT FORM 22 Rev 01/20 Accident Tracking No.: ECMC RECEPTION Receive Date: 02/19/2025 As required by Rule 602.f.404100162 ( )Fax: (720) 929-6317Phone: Zip:80217-3779COState:DENVER P O BOX 173779 Contact Name: City: Lynna Scranton Address: KERR MCGEE OIL & GAS ONSHORE LP Name of Operator: 47120ECMC Operator Number: Email:lynna_scranton@oxy.com ACCIDENT DATE, TIME, and LOCATION(Please be as specific as possible) Time of Accident:9:00 AMDate of Accident:02/18/2025 Type of Facility:LOCATIONAPI Number: 05-Facility ID:423918 Well/Facility Name:BUTTERBALL TANK BATTERY Well/Facility Num:25C-34HZ County:WELD Location: QTRQTR:SENW Sec:10 Twp:2N Rng:67W Meridian:6 Lat:40.154178 Long:-104.880073 Field Name:WATTENBERG Field Number:90750 Was there a reportable E & P waste spill or release associated with this accident?No Was there a Grade 1 Gas Leak associated with this accident ?No If YES, enter the Document Number of the Initial Spill/Release Report, Form 19: If YES, enter the Document Number of the Initial Spill/Release Report, Form 44: Yes Yes Subsequent Notice of Accident DESCRIPTION OF ACCIDENT Number of members of the general public injured:0 Number of workers injured:0 Number of general public fatalities:0 Number of worker fatalities:0 Type of Accident (check all that apply): Fire Explosion Detonation Uncontrolled Release Other Description: Vandalism Terrorism Hazardous Chemical Date Run: 2/25/2025 Doc [#404100162]Page 1 of 5 Lynna Scranton Signature:Title: Print Name:Email: Date: lynna_scranton@oxy.com I certify under penalty of perjury that this report has been examined by me and to the best of my knowledge is true, correct and complete. 02/19/2025HSE Director OTHER NOTIFICATIONS List all parties and agencies that were notified or responded to the accident. (For example: Local Government Designee, Municipality, County, BLM, EPA, CDOT, Local Emergency Planning Coordinator, etc.) Date Agency Contact Response OPERATOR COMMENTS and SUBMITTAL This form must be signed by an authorized agent of the entity making assertion. A fire tube failure on a 3-phase horizontal separator, due to corrosion, that resulted in a leak of process fluids which were ignited by the automated burner management system causing a fire contained at that vessel. Detailed Description of Accident: •Do not include names of injured, injuries, or medical treatment information. •Subsequent Report must include Root Cause. Firefighting Foam or Chemical Use Were firefighting foams/chemicals utilized?No If YES, please list the type, application percentage, and quantity of the firefighting foams/chemicals used: CONDITIONS OF APPROVAL, IF ANY LIST COA Type Description Prior to April 18, 2025, submit subsequent for 22 with root cause. Include documentation of policies, procedures, practices, and training implemented to prevent future incidents. 1 COA Date Run: 2/25/2025 Doc [#404100162]Page 2 of 5 User Group Comment Comment Date Stamp Upon Approval Total: 0 comment(s) General Comments Date Run: 2/25/2025 Doc [#404100162]Page 3 of 5 Date Run: 2/25/2025 Doc [#404100162]Page 4 of 5 ATTACHMENT LIST Att Doc Num Name Total Attach: 0 Files Date Run: 2/25/2025 Doc [#404100162]Page 5 of 5